Specifications
• General Specifications
Output impedance
<1 kΩ
AC bandwidth
40 to 400 Hz
Jaw opening
16 mm
Operating conditions 32 °F to 86 °F (0 °C to 30 °C) 90% RH;
86 °F to 104 °F (30 °C to 40 °C) 75% RH;
104 °F to 122 °F (40 °C to 50 °C) 45% RH
Storage conditions -22 °F to 140 °F (-30 °C to 60 °C) <90% RH
Altitude
Operate at less than 3000 metres
Weight
129 g
Dimensions
111 x 50 x 33 mm (H x W x D)
Standards
IEC1010-1 (1995);
EN61010-1 (2001) Category II 600 V, Category III 300 V
• Range Specifications
Function
Range
Output
Sensitivity Accuracy (of reading)
AC Current (50/60 Hz)
0 to 200 A 1 mV/A 1 A/mV AC ±2.0%±0.5 A
Using the Current Clamp with the PicoLog Software
1. Connect the output lead to the input sockets of the PicoLog CM3 Current
Data Logger.
2.
Connect the PicoLog CM3 to your computer using the USB cable supplied.
3. Position the Current Clamp perpendicular to and centered around the
conductor.
4. Run the PicoLog software on the computer.
5. Select
File > New Settings
and configure PicoLog for a ‘PLCM3’ device.
6. Select
File > New Data
and click the ‘Start recording’ button when ready.
DO194-1 Copyright © 2011 Pico Technology Ltd.