background image

PICO MACOM INC.

  

12500 Foothill Blvd.  •  Lakeview Terrace, CA 91342  •  (818) 897-0028  • (800) 421-6511 • FAX (818)824-7197

PFAM 550SUB & TBIF Positive Encoder

I N S TA L L A T I O N

RF OUT

IF IN

IF OUT

VIDEO

IN

AUDIO

IN

CAUTION: 

 FOR CONTINUED PROTECTION 

AGAINST

FIRE HAZARD REPLACE ONL

Y

 WITH 

THE SAME

TYPE 1/2 

A

 125 V FUSE 

AND RA

TING OF FUSE.

250 V

A

C

0.5A

600W  MAX

1

17 V

A

C

60 Hz 20 W

RF OUT

IF IN

IF OUT

VIDEO

IN

AUDIO

IN

CAUTION: 

 FOR CONTINUED PROTECTION 

AGAINST

FIRE HAZARD REPLACE ONL

Y

 WITH 

THE SAME

TYPE 1/2 

A

 125 V FUSE 

AND RA

TING OF FUSE.

250 V

A

C

0.5A

600W  MAX

1

17 V

A

C

60 Hz 20 W

CAUTION: 

 FOR CONTINUED PROTECTION 

AGAINST

FIRE HAZARD REPLACE ONL

Y

 WITH 

THE SAME

TYPE 1/2 

A

 125 V FUSE 

AND RA

TING OF FUSE.

RF OUT

IF IN

IF OUT

VIDEO

IN

AUDIO

IN

250 V

A

C

0.5A

600W  MAX

1

17V

AC

60 Hz 20 W

PF
AM 550

AGILE MODULA

T

O

R

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT

 OPEN

FUSE

+

+

+

+

+

+

+

RF

OUT

  1
17 V

A

C

60Hz10W

TBIF Encoder

OUT

OUT

INPUT

T

ru-Spec.

TM

R

DS75-2

5-600MHz SPLITTER

OUT

OUT

INPUT

T

ru-Spec.

TM

R

DS75-2

5-600MHz SPLITTER

OUT

OUT

INPUT

T

ru-Spec.

TM

R

DS75-2

5-600MHz SPLITTER

PF
AM 550

AGILE MODULA

T

O

R

PF
AM 550

AGILE MODULA

T

O

R

INPUT

DS75-3

T

ru-Spec.

TM

R

OUT

OUT

OUT

5-600MHz   SPLITTER

5.5dB

5.5dB

5.5dB

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT

 OPEN

FUSE

FUSE

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT

 OPEN

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT

 OPEN

T

O

 DISTRIBUTION

SYSTEM

T

O

 DISTRIBUTION

SYSTEM

T

O

 DISTRIBUTION

SYSTEM

I.F
. OUT

I.F
. IN

I.F
. OUT

I.F
. IN

I.F
. OUT

I.F
. IN

R.F

. OUT

600 MHz SPLITTER

600 MHz SPLITTER

600 MHz SPLITTER

600 MHz SPLITTER

8

Summary of Contents for PFAM-550SUB NTSC

Page 1: ...thill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 824 7197 FREQUENCY AGILE AUDIO AND VIDEO MODULATOR Doc No OM2960N 1 REV A PFAM 550SUB NTSC PICO MACOM INC U S A Spec Tru Installation And Operation Manual ...

Page 2: ... be followed 5 Cleaning Unplug this appliance from the wall outlet before cleaning Use a damp cloth for cleaning Do not use liquid cleaners or aerosol cleansers 6 Do Not Use Attachments not recommended by the manufacturer or they may cause hazards Important Information 7 Water and Moisture Do not use this product near water for example near a bathtub washbowl kitchen sink laundry tub in a wet base...

Page 3: ...personnel 18 Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water d If the product does not operate normally by following the operating i...

Page 4: ...utput Level 45 to 57 dBmv adjustable from front panel Output Impedance 75 ohm Output Return Loss 15 dB Audio Video Ratio Adjustable 7 to 22 dB below visual carrier Frequency Stability 5 KHz in aeronautical band Conforms to FCC Docket 21006 Spurious Output In band CATV channels 60dBc A V ratio 15dB In band Sub band 57 dBc A V ratio 15dB Out of Band F 550MHz 54 dBc A V ratio 15dB C N In Band 58 dB C...

Page 5: ...input or to scrambling device 13 Video Input Accepts video output from satellite receiver VCR and CCTV camera 14 Audio Input Accepts audio output from satellite receiver VCR and CCTV camera 15 SUB CATV When switch is in SUB position channels 7 to 13 are converted to T7 to T13 When switch is in CATV position CATV channels 2 to 78 and 95 to 99 are available 16 Fuse holder 117VACtype 0 5amp 125Vslow ...

Page 6: ...n until proper contrast is observed 6 Connect an audio source to the AUDIO IN on rear of the unit Set audio mod ulation peak deviation to 25 kHz with the audio modulation adjustment A known off air signal and a TV may be used to set adjust ment for equal audio level 7 Connect the RF OUTPUT to a proper combining network The Federal Communications Commission requires that cable system modulators whi...

Page 7: ...ow while even channels are combined on the other row of directional couplers The com biner loss is 16 dB per channel BS Denotes low medium high and superband 2 volt strip amps 72 Denotes low medium and high band 4 volt strip amps Also available for 220 VAC NTSC systems The final method of combining signals uses threehybridsplittersperheadendrack Theodd channels are combined in one splitter the eve...

Page 8: ...TENNA DSS RECEIVER PM45 6 VIDEO AUDIO AUDIO VIDEO OUT DSS RECEIVER PM45 8 VIDEO AUDIO DSS RECEIVER PM45 10 VIDEO AUDIO DSS RECEIVER VIDEO AUDIO PM45 12 SP860 2 SP860 4 SP860 5 SP860 7 SP860 9 SP860 11 SP860 13 SP860 T8 3 M X 7 MPA 25 AMPLIFIER RF RF RF VCR PFAM550SUB T8 VIDEO CAMERA PHC 12G CA 30 1000 DSB 21G SUB VHF DIPLEXER RF INPUT TV FAM RF T8 RETURN RF FAM RF RF AUDIO VIDEO RF T8 RETURN 4 WAY...

Page 9: ... OF FUSE RF OUT IF IN IF OUT VIDEO IN AUDIO IN 250 VAC 0 5A 600W MAX 117VAC 60 Hz 20 W PFAM 550 AGILE MODULATOR CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN FUSE RF OUT 117 VAC 60Hz10W TBIF Encoder OUT OUT INPUT Tru Spec TM R DS75 2 5 6 0 0 M H z S P L I T T E R OUT OUT INPUT Tru Spec TM R DS75 2 5 6 0 0 M H z S P L I T T E R OUT OUT INPUT Tru Spec TM R DS75 2 5 6 0 0 M H z S P L I T T E R PFAM 550 ...

Page 10: ...17VAC 60 Hz 20 W PFAM 550 AGILE MODULATOR CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN FUSE _ _ _ _ VIDEO OUT COMPOSITE OUT 70 MHz IN OUT AUDIO OUTPUT LEVEL VIDEO LEVEL RF IN 950 1450 MHz 18V 250mA LNB POWER OUT ON OFF 117V 35A 60Hz DATA CLOCK LANGUAGE GND _ MONO LEFT RIGHT AUDIO OUTPUT FUSE AC25OV 1 2A H V L R MONO INV NOR AUDIO OUTPUT CONNECTION CENTER CONDUCTOR TO MONO POS SHIELD TO MONO NEG PFAM...

Page 11: ...1 0 0 1 1 0 1 0 1 0 0 0 6 6 83 25 696 0 0 0 0 0 1 1 1 0 1 0 1 0 0 0 A 5 95 91 25 704 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 A 4 96 97 25 710 0 0 0 1 1 0 0 0 1 1 0 1 0 0 0 A 3 97 103 25 716 0 0 0 0 1 1 0 0 1 1 0 1 0 0 0 A 2 98 109 2750 722 0250 0 0 0 1 0 0 1 0 1 1 0 1 0 1 0 A 1 99 115 2750 728 0250 0 0 0 0 0 1 1 0 1 1 0 1 0 1 0 A 14 121 2625 734 0125 0 0 0 1 1 1 1 0 1 1 0 1 0 0 1 B 15 127 2625 740 0125 0 0 ...

Page 12: ...625 962 0250 0 0 0 1 0 0 0 0 1 1 1 1 0 0 1 JJ 46 355 2625 968 0250 0 0 0 0 0 1 0 0 1 1 1 1 0 0 1 KK 47 361 2625 974 0250 0 0 0 1 1 1 0 0 1 1 1 1 0 0 1 LL 48 367 2625 980 0250 0 0 0 0 1 0 1 0 1 1 1 1 0 0 1 MM 49 373 2625 986 0250 0 0 0 1 0 1 1 0 1 1 1 1 0 0 1 NN 50 379 2625 992 0250 0 0 0 0 0 0 0 1 1 1 1 1 0 0 1 OO 51 385 2625 998 0250 0 0 0 1 1 0 0 1 1 1 1 1 0 0 1 PP 52 391 2625 1004 025 0 0 0 0 1...

Page 13: ...0 0 0 1 1 1 0 0 0 1 0 0 MMM 75 529 25 1142 0 0 0 1 1 0 1 1 1 0 0 0 1 0 0 NNN 76 535 25 1148 0 0 0 0 1 1 1 1 1 0 0 0 1 0 0 OOO 77 541 25 1154 0 0 0 1 0 0 0 0 0 1 0 0 1 0 0 PPP 78 547 25 1160 0 0 0 0 0 1 0 0 0 1 0 0 1 0 0 THESE CHANNELS SHALL BE OFFSET IN ACCORDANCE WITH FCC RULING SECTION 76 612 C H A N N E L C H A N N E L C H A N N E L C H A N N E L C H A N N E L V I D E O V I D E O V I D E O V I ...

Page 14: ...be issued a Return Authorization RA number which will be used to track your product Be prepared to provide 1 The model number and channel number of the product 2 The date of purchase 3 A specific identification of the problem Deliver the products to Pico Macom Inc or ship the products in the original packing material at the address at the bottom of the page Include satisfactory evidence of the dat...

Page 15: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 824 7197 N O T E S ...

Page 16: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 824 7197 ...