Operation and Controls
OUTPUT
FUSE
117VAC
60Hz
TEST POINT
-20dB
INPUT
IN
IN
LO
GAIN
VHF
MAX
HI
FM TRAP
OUT
5W
MCM-30
31dB Adjustable VHF-Band
Distribution Amplifier
TRU SPEC
Front Panel
1.
Input:
Connect input cable to this port.
2.
FM Trap:
Place switch to the “IN” position to attenuate FM frequencies 88
to 96 MHz –20dB.
3.
FM Trap:
Place switch to the “IN” position to attenuate FM frequencies 95
to 108 MHz –20dB.
4.
LO Gain:
This potentiometer controls low band RF level.
5.
HI Gain:
This potentiometer controls high band RF level.
6.
Output:
Connect this port to the distribution system.
7.
Test Point:
The test point provides a port to monitor the output of the amplifier.
8.
Fuse:
Replace fuse with a 0.5A 250V fuse.
9.
LED:
Power is on when LED is lit.
10. Power Cord:
This three prong polarized power cord is approved by both UL and
CSA for safe operation of the amplifier. Do not cut the ground termi-
nal for both safety and operational reasons. Connect to 108 to 125
Vac, 50/60 Hz electrical outlet