background image

M860

3

Rev. 06/03

Ph: 800-421-6511

www.picomacom.com

Safeguards

11. Power Sources: 

This product should be operated only from the

type of power source indicated on the marking label. If you are not
sure of the type of power supplied to your home, consult your appli-
ance dealer or local power company.

12. Power-cord Protection:

Power-supply cords should be routed

so they are not likely to be walked on or pinched by items placed upon
or against them. Pay particular attention to cords and plugs, conven-
ience receptacles, and the point where they exit from the appliance.

13. Lightning:

For added protection for this product during a lightning

storm, or when it is left unattended or unused for long periods of time,
the unit should be disconnected from power source.

14. Power Lines:

An outside antenna system should not be located

in the vicinity of overhead power lines, other electric light or power cir-
cuits, where it can fall into such power lines or circuits. When installing
an outside antenna system, extreme care should be taken to keep
from touching such power lines or circuits as contact with them may
be fatal.

15. Overloading:

Do not overload wall outlets and extension cords as

this can result in risk of fire or electric shock.

16. Object and Liquid Entry:

Never push objects of any kind into this

product through openings as they may touch dangerous voltage
points or short-out parts that could result in a fire or electric shock.
Never spill liquid of any kind on the product.

17. Servicing:

Do not attempt to service this product yourself as

opening or removing covers may expose you to dangerous voltage or
other hazards. Refer all servicing to qualified service personnel.

18. Damage Requiring Service:

Unplug this product from the wall

outlet and refer servicing to qualified service personnel under the fol-
lowing conditions:

a.

When the power-supply cord or plug is damaged.

b.

If liquid has been spilled, or objects have fallen into the product.

c.

If the product has been exposed to rain or water.

d.

If the product does not operate normally by following the oper-

ating instruction. Adjust only those controls that are covered by
the operating instructions. An improper adjustment may result in
damage and will often require extensive work by a qualified tech-
nician to restore the product to its normal operation.

e.

If the product has been dropped or the cabinet has been

damaged.

f.

When the product exhibits a distinct change in performance—

this indicates a need for service.

19. Replacement Parts: 

When replacement parts are required, be

sure the service technician has used replacement parts specified by
the manufacturer or have the same characteristics as the original
parts. Unauthorized substitutes may result in fire, electric shock or
other hazards.

20. Safety Check:

Upon completion of any service or repairs to this

product, ask the service technician to perform safety checks to deter-
mine that the product is in proper operating conditions.

21. Outdoor Antenna Grounding:

Before attempting to install this

product, be sure the antenna or cable system is grounded so as to

provide some protection against voltage surges and built-up static
charges.

a.

Use No.10 AWG (5.3mm) copper, No.8 AWG (8.4mm) alu-

minum, No.7 AWG (10mm) copper-clad steel or bronze wire or
larger, as  ground wire.

b.

Secure antenna lead-in and ground wires to house with stand-

off insulators spaced from 4 feet (1.22m) to 6 feet (1.83m) apart.

c.

Mount antenna discharge unit as close as possible to where

lead-in enters house.

d.

A driven rod may be used as the grounding electrode where

other types of electrode systems do not exist. Refer to the
National Electrical Code, ANSI/NFPA 70-1984 for information.

e.

Use jumper wire not smaller than No.6 AWG (13.3mm) copper

or equivalent, when a separate antenna grounding electrode is
used.

 

 

  

NOTE TO THE CATV SYSTEM INSTALLER

THIS REMINDER IS PROVIDED TO CALL THE CATV SYSTEM
INSTALLER’S ATTENTION TO ARTICLE 820-22 OF THE NEC
THAT PROVIDES GUIDELINES FOR PROPER GROUNDING
AND, IN PARTICULAR, SPECIFIES THAT THE CABLE
GROUND SHALL BE CONNECTED TO THE GROUNDING
SYSTEM OF THE BUILDING, AS CLOSE TO THE POINT OF
CABLE ENTRY AS PRACTICAL.

Summary of Contents for M860

Page 1: ...Installation and Operation Manual M860 806MHz Channelized Agile CATV A V Modulator Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com ...

Page 2: ...bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat register This video produ...

Page 3: ...as been exposed to rain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has b...

Page 4: ...cent channel interference and assures accurate and spurious free output Superior out of band carrier to noise performance is achieved through band pass filtering at the output amplifier The modulator is shipped with all internal adjustments preset FCC Docket 21006 offsets are standard Pico Macom backs up this product with its industry leading 5 year limited warranty 125 Channel Range 54 806 MHz CA...

Page 5: ...onautical band Spurious Output 60 dB below video carrier with A V ratio 15 dB C N In Band 60dB C N Out of Band 65dB Fv 6 MHz Upper Adj Reject 60dBc Fv 1 5 MHz Lower Adj Reject 60dBc I F Frequency Video 45 75 MHz Audio 41 25 MHz Input Level 1 0 V p p min for 87 5 mod Input Type Clamped video neg sync Frequency Response 0 8 dB 30 Hz to 4 2 MHz Differential Gain 5 10 to 90 APL Differential Phase 5 10...

Page 6: ...ent Used to set video modulation adjust 14 Video Modulation Indicator Indicates video over modulation when lit 15 Output Level Used to set RF output level 16 30 dB Output test monitor Connect this port to monitor modulator RF output level Front Panel Control RF OUT EXT 4 5MHzIN IF OUT IF IN VIDEO IN AUDIO IN 117VAC 60Hz 38W 600W MAX 125VAC 0 5A CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD ...

Page 7: ...10W AUDIO IN 600W MAX L R CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN _ _ _ _ VIDEO OUT COMPOSITE OUT 70 MHz IN OUT AUDIO OUTPUT LEVEL VIDEO LEVEL RF IN 950 1450 MHz 18V 250mA LNB POWER OUT ON OFF 117V 35A 60Hz DATA CLOCK LANGUAGE GND _ MONO LEFT RIGHT AUDIO OUTPUT FUSE AC25OV 1 2A H V L R MONO INV NOR STEREO AUDIO CONNECTION Center Conductor to Left Positive Shield to Left Negative Center Conducto...

Page 8: ... return merchandise authorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully...

Reviews: