Page 4.3
HIGH DENSITY RELAY MODULES 40-145/146/148
pickering
SECTION 4 - PROGRAMMING GUIDE
MODULE ARCHITECTURE - 40-145 NORMALLY OPEN VERSIONS
One sub-unit is used to control all the module’s relays as shown below. Enabling a particular bit closes the C to A
signal path.
40-145-001 (50 x SPST)
The 40-145-001/101/201 are arrays of 50, 75 or 100 uncommitted SPST relays. In the default state, all signal paths
are open, energising a particular relay creates a signal path between the C and A terminals. The relay module’s
switching architectures are shown in their default state in the diagram below:
40-145-101 (75 x SPST)
A50
C50
A2
C2
A1
C1
A100
C100
A4
C4
A3
C3
A2
C2
A1
C1
A75
C75
A3
C3
A2
C2
A1
C1
Sub-Unit
Bit
40-145-001 Signal Path
(with relay energised)
40-145-101 Signal Path
(with relay energised)
40-145-201 Signal Path
(with relay energised)
1
1
C1 to A1
C1 to A1
C1 to A1
1
2
C2 to A2
C2 to A2
C2 to A2
1
3
C3 to A3
C3 to A3
C3 to A3
1
4
C4 to A4
C4 to A4
C4 to A4
1
49
C49 to A49
C49 to A49
C49 to A49
1
50
C50 to A50
C50 to A50
C50 to A50
1
51
—
C51 to A51
C51 to A51
1
52
—
C52 to A52
C52 to A52
1
74
—
C74 to A74
C74 to A74
1
75
—
C75 to A75
C75 to A75
1
76
—
—
C76 to A76
1
77
—
—
C77 to A77
1
97
—
—
C97 to A97
1
98
—
—
C98 to A98
1
99
—
—
C99 to A99
1
100
—
—
C100 to A100
40-145-201 (100 x SPST)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com