Coat the reamer with
grease (e.g. 60200035)
to bind the removed
material.
2.4.
Slide the selected guide to the start of the reamer. Place the reamer with the guide beside the glow plug,
making sure the threads
line up
.
2.5. Screw in the guide in the glow plug shaft first until it stops. Then back off half a turn and carefully slide the
reamer into the glow plug shaft.
2.6. Place the actuator on the square of the reamer and clamp it.
X
The length "X" may never exceed the distance "A" other wise
the reamer is clamped in the glow plug shaft when screwing in
the guide!
Reamer
Guide