41
English
FLAMMABLE WALLS:
the fi replace may be installed near fl ammable
walls provided suitable protection consisting of insulating and non-
combustible material is inserted.
To insulate the stove and to install the surround correctly, construct
a lining wall in non-fl ammable material (e.g. plasterboard) and in-
sert a 8 cm thick layer of insulating material between the two walls.
Always leave a gap of 10 cm between the stove and the lining wall.
(fi g. 20)
NON-FLAMMABLE WALLS:
always leave a gap of 5 cm between the
stove and the lining wall. (fi g. 21)
Minimum distance from the ceiling means the distance
between connection to the fl ueway and any elements lo-
cated above it (e.g. beams).
FLAMMABLE CEILING:
insulate the top part of the fi replace with 8
cm of insulating material and create a false ceiling of non-fl ammable
material with at least 8 cm of insulating material. (Fig. 22)
The minimum distance between the false ceiling and connection to
the fl ueway must be 20 cm, while the fl ue connection must be insu-
lated with at least 3 cm thick non-fl ammable material that is resistant
to high temperatures.
If the surround canopy and the fl ue connection are metal, the mini-
mum distance from the false ceiling may be reduced to 10 cm, but
the insulation of the connection to the fl ueway must be at least 6 cm
thick.
NON-FLAMMABLE CEILING:
the minimum distance between
the ceiling and connection to the fl ueway must be 20 cm. (fi g. 22)
If the fl oor is made of fl ammable material, always leave a gap of 24
cm between the stove and the fl oor.
The heat radiation area is considered as being from the hearth ope-
ning up to 1 metre away both to the front and the side. No fl ammable
element must be placed within this area, such as: carpets, curtains,
wood furniture, ornaments, fl ammable liquids, fi re-lighting products
or fi rewood, etc.
Failure to comply with the above could cause a fi re!!!
Fig. 20
Fig. 21
3 CM DI ISOLANTE TERMICO
Fig. 22
DT2030265-00
DT2030266-00
DT2030267-00
FLAMMABLE WALLS
10 cm air gap
Lining wall in fire retardant
material such as plasterboard
8 cm insulating
material
Surround depth
NON-FLAMMABLE WALLS
5 cm air gap
Surround
depth
Ceiling in flammable material
8 cm insulating material
8 cm insulating material
1.10 MINIMUM SAFETY DISTANCES - Fig. 20 / 23
DT2010174-02
Walls
Ceiling
Floor
Dangerous heat radiation
area