Besides, upon pre-delivery it is therefore necessary to check the battery charge and recharge it, if
required, before storing the vehicle and, afterwards, every six months.
INSTRUCTIONS FOR THE BATTERY REFRESH AFTER OPEN-CIRCUIT STORAGE
1) Voltage check
Before installing the battery on the vehicle, check the open circuit voltage with a regular tester.
- If voltage exceeds 12.60 V, the battery can be installed without any renewal recharge.
- If voltage is below 12.60 V, a renewal recharge is required as explained in 2).
2) Constant voltage battery charge mode
- Constant voltage charge equal to 14.40 ÷ 14.70V
- Initial charge voltage equal to 0.3 ÷ 0.5 for Nominal capacity
- Charge time:
10 to 12 h recommended
Minimum 6 h
Maximum 24 h
3) Constant current battery charge mode
- Charge current equal to 1/10 of the nominal capacity of the battery
- Charge time: 5 h
CAUTION
NEVER USE FUSES WITH A CAPACITY HIGHER THAN THE RECOMMENDED CAPACITY. USING
A FUSE OF UNSUITABLE RATING MAY SERIOUSLY DAMAGE THE VEHICLE OR EVEN CAUSE
A FIRE.
CHARGE THE BATTERY BEFORE USE TO ENSURE OPTIMUM PERFORMANCE. INADEQUATE
CHARGING OF THE BATTERY WITH A LOW ELECTROLYTE LEVEL BEFORE IT IS FIRST USED
SHORTENS THE LIFE OF THE BATTERY.
IF THE VEHICLE IS NOT USED FOR SOME TIME (1 MONTH OR MORE) THE BATTERY NEEDS
TO BE RECHARGED PERIODICALLY. THE BATTERY RUNS DOWN COMPLETELY IN THE
COURSE OF THREE MONTHS. IF IT IS NECESSARY TO REFIT THE BATTERY IN THE VEHICLE,
BE CAREFUL NOT TO REVERSE THE CONNECTIONS TAKING INTO ACCOUNT THAT THE
GROUND WIRE (BLACK) MARKED(-) MUST BE CONNECTED TO THE - NEGATIVE TERMINAL
WHILE THE OTHER TWO RED WIRES MARKED (+) MUST BE CONNECTED TO THE TERMINAL
MARKED WITH THE +POSITIVE SIGN
WARNING
WHEN THE BATTERY IS REALLY FLAT (WELL BELOW 12.6V) IT MIGHT OCCUR THAT 5 HOURS
OF RECHARGING ARE NOT ENOUGH TO ACHIEVE OPTIMAL PERFORMANCE.
GIVEN THESE CONDITIONS IT IS HOWEVER ESSENTIAL NOT TO EXCEED 8 HOURS OF CON-
TINUOUS RECHARGING SO AS NOT TO DAMAGE THE BATTERY ITSELF.
Dry-charge battery
- Remove the battery ventilation duct closing cap and remove the caps from the single elements.
- Fill the battery with electrolyte having a density of 1.270+/-0.01 Kg/l (corresponding to 31+/-1 Bé) with
minimum ambient temperature of 15 °C, up to the top level indicated on the single block.
- Slightly tilt the battery to remove any air bubbles formed during the filling.
- Place the caps on the filling holes of the single elements without tightening them and let the battery
stand. During this phase, the battery undergoes a gasification phenomenon and temperature rises.
MSS X9 Evolution 250
Electrical system
ELE SYS - 73
Summary of Contents for MSS X9 EVOLUTION 250
Page 1: ...WORKSHOP MANUAL 618153 MSS X9 Evolution 250 ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 19: ...INDEX OF TOPICS TOOLING TOOL ...
Page 31: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 46: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 52: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 77: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 80: ...INDEX OF TOPICS ENGINE ENG ...
Page 116: ...Engine MSS X9 Evolution 250 ENG 116 ...
Page 148: ... Remove the maximum nozzle Remove diffuser Engine MSS X9 Evolution 250 ENG 148 ...
Page 172: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 181: ...stand retaining bolt 20 25 MSS X9 Evolution 250 Suspensions SUSP 181 ...
Page 182: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 191: ...MSS X9 Evolution 250 Braking system BRAK SYS 191 ...
Page 192: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 193: ...Circuit diagram MSS X9 Evolution 250 Cooling system COOL SYS 193 ...
Page 203: ...Thermostat cover screws 3 4 MSS X9 Evolution 250 Cooling system COOL SYS 203 ...
Page 204: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 215: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 219: ...INDEX OF TOPICS TIME TIME ...