START-UP PROBLEMS
No fuel in tank
Refuel
Filters, jets or carburettor body
dirty or clogged.
Contact an
Authorised Service
Centre.
Insufficient battery charge
Recharge the battery.
I
GNITION
PROBLEMS
No spark from spark plug. Due to
the presence of high voltage, this
check should only be carried out by
an expert.
Check that the electrodes are
properly adjusted (0.7÷ 0.8 mm).
Check that the electrodes are
clean (use pure petrol and a metal
brush or an emery cloth). Check
the spark plug insulator: Replace
the spark plug if the insulator is
cracked or broken. If the spark plug
is in good conditions, contact an
Authorised Service Centre.
L
ACK
OF
COMPRESSION
Spark plug adapter "worn", valve
clearance not adequate; worn
piston gas rings
Contact an
Authorised Service
Centre.