Page 13 of 30
f.
Connecting integrated solenoid valve (V2) with vacuum sensor version
Pos.
Description
A
Compressed air connection
G 1/8” for
solenoid valve
B
Compressed air connection
G 1/8” for blow off
or vacuum monitoring
C
Solenoid valve, vacuum and blow-off N.C. / N.C.
D
Vacuum sensor
E
Connector M8 3 pin male
Solenoid valves characteristics
Fluid
Air
Operating pressure range (MPa/psi)
0.15-0.7/22-87psi
Operating temperature (°C/F)
-10 +50 / 14-122 without icing
Manual override
Non-locking push type
Lubrication
Not required
Impact/Vibration resistance (m/s²)
150/30
Electrical connection
M12 4 pin waterproof connector, Male
Coil rated voltage (Vcc)
24
Allowable voltage
± 10% rated voltage
Current consumption (mA)
27
Surge voltage suppressor
Zener Diode
Indicator light
LED
Solenoid valve A
Vacuum
Solenoid valve B
Blow off
►
M8 connector has an indication of IP65 (enclosure) that give protection to dust and water. Take note,
however, that the product is not designed to be used in contact with water.
►
Do not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0.4 to
0.6 Nm, (0.30 to 0.44 lbf))
►
The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution
and do not apply a stress of 30 N (6.74 lbf ) or greater.
►
Torque couple of mounting screw M3: 0.8 Nm (0.59 lbf). Put attention at the direction of mounting for
electro valve and seal.