You have read and understood the user manual for the electronics.
✓
You have installed the electronics properly.
✓
The electronics are switched off.
✓
The V-412.xx6025E0 is connected to the
protective earth conductor (p. 16)
.
NOTICE
Damage due to incorrect connection of the V-412.xx6025E0!
Connecting unsuitable electronics or the wrong cable can lead to damage to the
V-412.xx6025E0 or the electronics.
►
Make sure that the electronics support the drive type of the V-412.xx6025E0 and has been
configured accordingly.
►
Use cables from PI miCos only to connect the V-412.xx6025E0 to the electronics.
►
Pay attention to correct
Connecting the V-412.xx6025E0
1. If necessary: Remove the ESD protective caps from the connectors of the V-412.xx6025E0.
2. All of the V-412.xx6025E0's connections must be made in the following order:
a) Optional: Purge air connector
Permissible pressure: 2 to 6 bar (200 to 600 kPa)
b) Drive connector
c) Linear encoder connector
3. Secure the connectors against unintentional removal.
4. If necessary: Turn the drive and encoder connector carefully to a position suitable for your
installation conditions.
The drive and encoder connector of the V-412.xx6025E0 can be turned up to 180° (in steps
of approximately 7°).
Figure 9: Rotating the V-412.xx6025E0's drive/sensor connectors
6 INSTALLATION
V412M0008EN
‒
5/11/2020
20