PI PIMag V-27 Series Short Instructions Download Page 3

MP162EK 1.1.0 09/2019. 0.3

The linear actuator can overheat during 

continuous operation outside of the specified 

parameters. Overheating can damage the linear 

actuator. Heat produced during operation can 

affect your application.

 

X

Ensure sufficient ventilation and heat dissi-

pation from contact surfaces.

 

X

Install the linear actuator so that the appli-

cation is not affected by dissipating heat.

 

X

Pay attention to the permissible values for 

nominal and peak current (see manual).

Startup

The drive of the linear actuator is not self­ 

locking. If servo control is switched off, the 

linear actuator could move unexpectedly and 

the runner or the contact part could collide 

with the hard stop or objects in the workspace.

 

X

If the linear actuator or the axis is aligned 

vertically or is tilted (only V­275, V­277): 

Perform an autozero procedure on the 

controller for the axis (see manual for the 

controller).

 

X

Take suitable precautionary measures to 

prevent unintentional motion before  

switching off or rebooting the controller.

 

X

Move to the travel range limits only with 

low velocity and force.

The nominal current as specified in the manual 

applies when operating at room temperature.

 

X

Adjust the nominal current needed for 

operating the actuator when the ambient 

temperature rises (see user manual).

 

X

Adapt your application (acceleration, 

speed, load) so that the calculated nominal 

current is not exceeded. If you have any 

questions, contact our customer service 

department.

Defective software or incorrect operation of 

the software can result in unintentional motion.

 

X

Do not place any objects in areas where 

they can be caught by moving parts.

Travel to the hard stop with maximum force or 

at high velocity can cause damage, excessive 

heat or considerable wear to the mechanics.

 

X

Stop the motion immediately if a controller 

malfunction occurs.

 

X

Ensure that the end of the travel range is 

approached at low velocity and with low 

force.

 

X

Set the control signal so that the runner 

does not stop abruptly or try to continue 

motion at the end of the travel range.

 

X

Determine the maximum velocity for your 

application.

Uncontrolled oscillation can damage your appli-

cation or the linear actuator.

 

X

If oscillation occurs, switch the servo mode 

off or stop the linear actuator immediately.

 

X

Check the servo control parameter settings 

(see manual).

Moisture, liquids, and electrically conductive 

materials (e.g., metal dust) that penetrate the 

linear actuator can damage it.

 

X

Operate the linear actuator only within 

the permissible ambient conditions (see 

manual).

Excessively high or wrongly connected opera-

ting voltages can cause damage to the linear 

actuator.

 

X

Use compatible electronics only.

 

X

Pay attention to the operating voltage  

range of the linear actuator (see manual).

 

X

Pay attention to the correct pin assignment 

(see manual).

M O T I O N   |   P O S I T I O N I N G