Safety Precautions 

 

NOTICE 

 

Damange due to manual displacement! 

Manual displacement can cause irreparable damage to the piezo modules in the 
NEXACT® linear motor. 

  Do not displace the moving platform of the PIFOC® Z-drive with NEXACT® 

linear motor manually! 

 

 

NOTICE 

 

Fixed operation frequency for permanent operation! 

  For permanent operation of the drives do not exceed operation frequencies of 

800 Hz. 

 

 

NOTICE 

 

Unsuitable cables! 

Unsuitable cables can damage the electronics. 

  Only use cables from PI for connecting the N-725.2A to the electronics. 

 

 

INFORMATION 

 

Extended cables can affect the performance of the N-725.2A. 

  Do 

not

 use cable extensions. If you need longer cables, contact our customer 

service department (p. 6). 

 
 
 

Installation 

Connecting the N-725.2A to a Protective Earth Conductor 

 

NOTICE 

 

Ground loops with double connection of protective earth conductor! 

In the case of Z drives with Sub-D connectors, ground loops can occur when the Z 
drive is grounded via its protective earth connection as well as by the shield of the 
connection cable for the electronics. 

  If a ground loop occurs, contact our customer service department (p. 6). 

 
The N-725.2A is grounded when it is connected to the piezo controller via its HD sub-D15m 
connector. However, to comply with the 2004/108/EC, EMC Directive, a functional grounding is 
required for potential equalization. 
 

Summary of Contents for PIFOC N-725.2A

Page 1: ...tents System Description 2 Symbols and Typographic Conventions 2 Intended Use 2 Safety Precautions 3 Installation 3 Connecting the N 725 2A to a Protective Earth Conductor 3 Fastening the N 725 2A 5 S...

Page 2: ...avoid the situation NOTICE Dangerous situation If not avoided the dangerous situation will result in damage to the equipment Actions to take to avoid the situation INFORMATION Information for easier...

Page 3: ...use cables from PI for connecting the N 725 2A to the electronics INFORMATION Extended cables can affect the performance of the N 725 2A Do not use cable extensions If you need longer cables contact...

Page 4: ...d washer 3 Flat washer 4 Cable lug 5 N 725 2A case with protective earth connection M4 threaded hole and protective earth conductor symbol 6 Protective earth conductor 1 If necessary fasten a suitable...

Page 5: ...eral Notes on Start Up and Operation NOTICE Uncontrolled oscillation Oscillations can cause irreparable damage to the Z drive Oscillations are indicated by a humming and can result from the following...

Page 6: ...ean the surface of the N 725 2A with a towel that is lightly dampened with a mild cleanser or disinfectant with alcohol or with isopropanol Do not do any ultrasonic cleaning Customer Service For inqui...

Page 7: ...or Optical Open loop travel 2 5 mm 0 2 mm Closed loop travel 2 mm Min incremental motion 5 nm typ Mechanical properties Push pull force capacity in motion direction 10 10 N max Drive properties Piezoc...

Page 8: ...A Physik Instrumente PI GmbH Co KG_Auf der Roemerstrasse 1_76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 E mail info pi ws www pi ws Dimensions Decimal places are separated in comma...

Page 9: ...ved for the N 725 2A Area of application For indoor use only Maximum altitude 2000 m Air pressure 1100 hPa to 0 1 hPa corresponds to roughly 825 torr to 0 075 torr Relative humidity Highest relative h...

Page 10: ...f in the member states of the EU with other wastes When disposing of your old equipment observe the international national and local rules and regulations To meet the manufacturer s product responsibi...

Reviews: