5 Installation
P-88x/P-08x Piezo Actuator
PZ259E
Version: 1.1.0
29
Models without stranded wires: You have soldered a red stranded wire to the positive
electrode (+) and a black stranded wire to the negative electrode (-) of the P-88x/P-08x
(p. 22).
Tools and accessories
P-890.xx coaxial cable (p. 13), LEMO to open end (can be ordered separately)
Suitable soldering iron
Suitable solder
Suitable cable tools
Connecting the P-88x/P-08x to the electronics
1.
If necessary, shorten the wire and the cable shield of the coaxial cable to the correct
length.
2.
Make the stranded wires of the P-88x/P-08x accessible:
−
When the stranded wires of the P-88x/P-08x are short-circuited, disconnect the
connection between the stranded wires.
−
Remove all aids and components that have been connected to the P-88x/P-08x for
short-circuiting or discharging (e.g., conductive rubber or discharging resistor).
3.
Solder the red stranded wire of the P-88x/P-08x to the wire of the coaxial cable
connected to the inner contact of the LEMO connector.
4.
Solder the black stranded wire of the P-88x/P-08x to the cable shield of the coaxial
cable.
5.
Insulate the soldered cable connections in a suitable manner.
6.
Connect the connector of the P-88x/P-08x to the corresponding connection on the
electronics.