10 Technical Data
N-412 Piezo Motor Rod Drive
N412T0001
Version: 1.2.1
21
10.1.2
Maximum Ratings
N-412 linear drives are designed for the following operating data:
Maximum operating voltage Maximum operating
frequency
Maximum power
consumption
48 V
pp
23 kHz
15 W
10.1.3
Ambient Conditions and Classifications
The following ambient conditions and classifications must be observed for the N-412:
Area of application
For indoor use only
Maximum altitude
2000 m
Air pressure
1100 hPa to 0.1 hPa
Relative humidity
Highest relative humidity 80 % for temperatures up to 31 °C
Decreasing linearly to 50 % relative humidity at 40°C
Operating temperature
0 °C to 50 °C
Storage temperature
-20 °C to 75 °C
Transport temperature
-20 °C to 75 °C
Overvoltage category
II
Protection class
I
Degree of pollution
1
Degree of protection
according to IEC 60529
IP30