PI E-5 Series Short Instructions Download Page 2

PZ300EK 1.1.0 04/2021. 1.0

M O T I O N   |   P O S I T I O N I N G

Intended Use

The electronics are a laboratory device as 

defined by DIN EN 61010-1. They are intended 

for indoor use and use in an environment which 

is free of dirt, oil, and lubricants.
According to their design, the electronics are 

intended for operating positioners with piezo 

drive from PI.
The electronics may only be used in compliance 

with the technical specifications and instruc-

tions in the user manual. The user is responsible 

for process validation.
The electronics may only be installed, operated, 

maintained, and cleaned by authorized and 

appropriately qualified personnel.

Unpacking

The electronics contain electrostatic-sensitive 

devices. Improper handling can damage the 

electronics.

 

X

Do not touch the contacts in the connec-

tors for the electronics.

Installing

Touching any conductive parts carrying line 

voltage can result in serious injury or death 

from electric shock.

 

X

Do not open the electronics.

 

X

Pull the power plug for the electronics out 

before replacing the fuses of the electro-

nics.

If a protective earth conductor is not or not 

properly connected, touching the electronics 

can lead to death from electric shock or to seri-

ous injury in the case of a malfunction.

 

X

Operate the electronics only with a proper-

ly connected protective earth conductor.

 

X

Do not remove the protective earth 

conductor form the electronics during 

operation.

 

X

Pay attention to the applicable standards 

for the protective earth conductor connec-

tion.

Connecting a positioner with an incompatible 

drive type to the electronics can cause irrepara-

ble damage to the positioner or the electronics. 

Even positioners with mechanically compatible 

connectors may not be electrically compatible 

with the electronics.

 

X

Only connect compatible positioners to the 

electronics.

Unsuitable cables can cause damage to the 

electronics and can affect the performance of 

the positioner.

 

X

Use original PI parts only.

High temperatures can cause the electronics to 

overheat.

 

X

Set up the electronics with a gap of at least 

10 cm to the top and rear panels and at 

least 5 cm to the sides. If this is not pos-

sible, make sure that the surroundings are 

cooled sufficiently.

 

X

Ensure sufficient ventilation at the place of 

installation.

 

X

Keep the ambient temperature at a noncri-

tical level (5 to 40 °C).

Systems consisting of positioners and electro-

nics are calibrated at the factory to achieve 

optimum performance. Replacing system 

components will cause a loss in positioning 

accuracy.

 

X

Pay attention to each individual channel 

assignment when connecting several positi-

oners to the electronics.

Starting and Operating

Thermal instability could reduce the perfor-

mance of the electronics directly after they are 

switched on.

 

X

If possible, switch on the electronics one 

hour before using the system.

 

X

Make sure that you can disconnect the 

power plug from the mains at any time. 

Securing the Electronics

Requirements

 

The electronics are switched off.

General Safety 

Information

Installing

Reviews: