PI E-4 Series Short Instructions Download Page 3

PZ300EK 1.0.0 08/2020. 1.0

M O T I O N   |   P O S I T I O N I N G

Securing the Electronics

When the electronics are to be used as a bench-

top device:

 

X

Make sure that the electronics are standing 

safely and securely.

If the electronics are to be mounted:

1.  Bore the required holes into the underlying 

surface.

2.  Insert a suitably sized screw into each 

hole or recess and tighten to secure the 

electronics.

Connecting the Electronics to the Pro

-

tective Earth Conductor

Requirements

 

The electronics are switched off.

Tools and Accessories

 

Suitable protective earth conductor:

 

Cable cross section ≥0.75 mm²

 

Contact resistance <0.1 Ω at 25 A at 

all points relevant for attaching the 

protective earth conductor 

 

Mounting hardware for the protective 

earth conductor; is on the protective earth 

connector on delivery of the electronics

 

Suitable wrench

Connecting the Protective Earth Conductor

1.  Attach a suitable cable lug to the protective 

earth conductor.

2.  Attach the cable lug to the protective earth 

connector using the mounting hardware 

supplied.

Connecting the Protective Earth Conductor 

with a Threaded Bolt

Threaded bolt

Flat washer

Cable lug with protective earth conductor

Lock washer

Nut

Connecting the Electronics to the Power 

Supply

 

NOTICE

Electronics with integrated power ad-

apter are factory set to the line voltage 

customary in your country. It may be 

necessary to install different line power 

fuses to operate in other countries (see 

manual).

Requirements

 

The electronics are switched off.

 

The power cord is not connected to the 

power socket.

Tools and Accessories

 

If necessary: Power adapter supplied

 

If necessary: Adapter supplied for the pow-

er adapter connector

 

Power cord supplied

Connecting the Power Adapter to the Electro

-

nics using the Cable Adapter

1.  Connect the cable adapter to the power 

adapter connector of the electronics.

2.  Connect the power adapter to the cable 

adapter.

3.  Connect the power cord to the power 

adapter.

Connecting the Power Adapter to the Electro

-

nics without Cable Adapter

1.  Connect the power adapter to the power 

adapter connector on the electronics.

2.  Connect the power cord to the power 

adapter.

Connecting the Power Cord Directly to the 

Electronics

 

X

Connect the power cord to the power 

socket on the electronics.

Function Test

If the electronics have a display, a function 

test is recommended before a positioner is 

connected.

Requirements

 

The electronics are switched off.

 

A positioner is not connected to the elec-

tronics

Summary of Contents for E-4 Series

Page 1: ...d maintenance require additional information from the manuals for the electronics and or the positioner Manuals may be titled as follows User Manual Technical Note Downloading the manuals and the software from the website If you received a CD from PI with the PI Software Suite follow the instructions in the Manuals A000T0081 Downloading Manuals from PI pdf file on the CD If the product was supplie...

Page 2: ... during operation X Pay attention to the applicable standards for the protective earth conductor connec tion Connecting a positioner with an incompatible drive type to the electronics can cause irrepara ble damage to the positioner or the electronics Even positioners with mechanically compatible connectors may not be electrically compatible with the electronics X Only connect compatible positioner...

Page 3: ...able lug with protective earth conductor 4 Lock washer 5 Nut Connecting the Electronics to the Power Supply NOTICE Electronics with integrated power ad apter are factory set to the line voltage customary in your country It may be necessary to install different line power fuses to operate in other countries see manual Requirements The electronics are switched off The power cord is not connected to ...

Page 4: ...e positioner to move Apply a suitable input control signal to the CONTROL INPUT refer to manual or us the DC OFFSET potentiometer Starting and Operating Controller Closed Loop Operation 1 Proceed as follows for each channel a If a control signal is connected to the CONTROL INPUT socket set it to 0 V b If available Turn the DC OFFSET poten tiometer counterclockwise to 0 c Move the SERVO switch to t...

Page 5: ...equipment made available to the market after 13 August 2005 If you have an old device from PI you can send it to PI free of charge Companies Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 info pi de www pi ws PI miCos GmbH Freiburger Strasse 30 79427 Eschbach Germany Phone 49 7634 5057 0 Fax 49 7634 5057 99 info pimicos com...