Manual I1AM02
MA 1296-A010 EN
24
i
CAUTION
– Possible damage!
Damage of the module by wrong connection..
- Do not exchange the 10 pin connector for limit switches with the
10 pin connector for the encoder evaluation.
- Please observe the supply voltage of the encoder: 5 V or 15 V
- Also ensure that the encoder is configured correctly in its
programming. The connection of an incremental encoder and
parameterising for SSI can cause damage.
Encoder - Technical Specification
Encoder type
Supply
Resolution Supported types
Differential
5 V / 5.5 V;
500 mA
2
32
Quadratur with zero track
up to 4 MHz
SSI
5 V / 5.5 V;
500 mA
2
31
SSI
BiSS
5 V / 24 V;
500 mA
2
31
BiSS-C
BiSS-B
Endat
5 V / 5.5 V;
500 mA
2
31
Endat
01
02
21
22
T
Resolver
5 to 10 V
rms
;
1 to 10 kHz
2
12
Resolver 6-wire
LVDT / RVDT
4-/5-/6-wire
Summary of Contents for phyMOTIONT I1AM02.1
Page 9: ...phytron 9 MA 1296 A010 EN 4 Technical Data 4 1 Declaration of Incorporation...
Page 10: ...Manual I1AM02 MA 1296 A010 EN 10...
Page 30: ...Manual I1AM02 MA 1296 A010 EN 30 Fig 6 6 wire LVDT RVDT wiring...
Page 31: ...phytron 31 MA 1296 A010 EN Synchronisation Fig 7 Synchronisation wiring...