Start Up Instructions phyCORE-TC1775
PHYTEC Technologie Holding AG
2002
Date: 01.08.02
Techn. Hotline Europe: +49 (6131) 9221-31
http://www.phytec.de
Techn. Hotline America: 1-800-278-9913
http://www.phytec.com
LAN-014e_1
2/2
A. Start Up with the Debugger Integrated in the Development
Environment:
1.
Place the module on the pin header rows located in the middle of the
Development Board.
2.
Be sure that the insertable jumper JP10 is closed. This activates the
OCDS1-Wiggler on the Development Board.
3.
Connect the phyCORE-TC1775 to connector X6 on the Development Board
using the ribbon band cable "OCDS1-debug-cable" included in the kit. Be
sure to note the orientation of the ribbon cable‘s red wire indicating pin 1.
4.
Connect the included DB25 cable to the parallel interface on your host PC.
5.
Connect the included 5 V voltage adapter to socket X1 on the Development
Board. All three "power-good" LED‘s should illuminate.
6.
The phyCORE-TC1775 is now ready to be connected to the debugger of your
software development environment.
B.
Start Up with the On-Chip Bootstrap Loader of the
TriCORE-TC1775
1.
Place the module on the pin header rows located in the middle of the
Development Board.
2.
Be sure that the insertable jumper JP10 is open. This deactivates the
OCDS1-Wiggler on the Development Board.
3.
Using the RS-232 cable included in the kit, connect the lower DB-9 socket
(P1) on the Development Board to one of the serial interfaces on your host
PC.
4.
Using the included power adapter, connect the 5 V supply voltage to socket
X1 on the Development Board. All three "power-good" LED‘s should
illuminate.
5.
Simultaneously press the Reset and Boot buttons on the Development Board,
first releasing the Reset and then, two or three seconds later, release the Boot
button. This sequence of pressing and releasing the Reset and Boot buttons
renders the phyCORE-TC1775 into the Bootstrap mode.
6.
The phyCORE-TC1775 is now waiting for a connection to an appropriate PC
software (i.e. „Hitex TC1775 Programmer“).