phyCORE-LPC2292/94
96
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
2.
No CAN transceiver is populating the phyCORE-LPC2292/94 and
Jumpers J602 and J604 are closed; CAN signals generated by the
CAN transceiver (U2) on the Carrier Board extending to connector
P2A
without galvanic seperation:
Jumper Setting
Description
JP31
1 + 2
Pin 2 of the DB-9 plug P2A is connected to CAN_L1
from transceiver on the Carrier Board HD200
JP32
1 + 2
1
Pin 7 of the DB-9 plug P2A is connected to CAN_H1
from transceiver on the Carrier Board HD200
JP11
2 + 4
Input at opto-coupler U4 on the phyCORE
Carrier Board HD200 connected with
CAN_H1/TD1 of the phyCORE-LPC2292/94
JP12
2 + 4
Output at opto-coupler U5 on the phyCORE Carrier
Board HD200 connected with
CAN_L1/RD1 of the phyCORE-LPC2292/94
JP13
2 + 3
Supply voltage to CAN transceiver and opto-coupler on
the phyCORE Carrier Board HD200
JP18
1 + 2
GND potential at CAN transceiver and opto-coupler on
the phyCORE Carrier Board HD200
JP29
open
No power supply via CAN bus
JP39
open
No power supply via CAN bus
Table 57:
Jumper Configuration for CAN Plug P2A using the CAN Transceiver
on the Carrier Board HD200
Pin 3:
GND (Carrier Board Ground)
Pin 7:
CAN_H1 (not galvanically separated)
Pin 2:
CAN_L1 (not galvanically separated)
Pin 6:
GND (Carrier Board Ground
Figure 25: Pin Assignment of the DB-9 Plug P2A (CAN Transceiver on Carrier
Board)
1
: Please make sure the CAN transceiver on the phyCORE-LPC2292/94 is not populated and
Jumpers J602 and J604 are closed (
refer to section 3.14 for details
).
1
2
3
4
7
6
5
8
9
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...