The phyCORE-LPC2292/94 on the phyCORE Carrier Board
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
95
16.3.7
First CAN Interface at Plug P2A
Plug P2A is the lower plug of the double DB-9 connector at P2. P2A
is connected to the first CAN interface (CAN1) of the
phyCORE-LPC2292/94 via jumpers. Depending on the configuration
of the CAN transceivers and their power supply, the following three
configurations are possible:
1.
CAN transceiver populating the phyCORE-LPC2292/94 is
populated and the CAN signals from the module extend directly to
plug P2A.
Jumper Setting
Description
JP31
2 + 3
Pin 2 of the DB-9 plug P2A is connected to CAN_L1
from on-board transceiver on the phyCORE module
JP32
2 + 3
Pin 7 of the DB-9 plug P2A is connected to CAN_H1
from on-board transceiver on the phyCORE module
JP11
open
Input at opto-coupler U4 on the phyCORE
Carrier Board HD200 open
JP12
open
Output at opto-coupler U5 on the phyCORE Carrier
Board HD200 open
JP13
open
No supply voltage to CAN transceiver and opto-coupler
on the phyCORE Carrier Board HD200
JP18
open
No GND potential at CAN transceiver and opto-coupler
on the phyCORE Carrier Board HD200
JP29
open
No power supply via CAN bus
JP39
open
No power supply via CAN bus
Table 56:
Jumper Configuration for CAN Plug P2A using the CAN Transceiver
on the phyCORE-LPC2292/94
Pin 3:
GND
(Carrier Board Ground)
Pin 7:
CAN_H1 (not galvanically separated)
Pin 2:
CAN_L1 (not galvanically separated)
Pin 6:
GND
(Carrier Board Ground)
Figure 24: Pin Assignment of the DB-9 Plug P2A (CAN Transceiver on
phyCORE-LPC2292/94, Front View)
1
2
3
4
7
6
5
8
9
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...