![Phytec phyCORE-i.MX31 Hardware Manual Download Page 71](http://html1.mh-extra.com/html/phytec/phycore-i-mx31/phycore-i-mx31_hardware-manual_1554149071.webp)
The phyCORE-i.MX on the Development Board
©
PHYTEC Messtechnik GmbH 2007 L-700e_0
61
Figure 16: phyMAP-i.MX31 jumper placement and numbering
Table 16: phyMAP-i.MX31 solder jumpers and signal routing
J
UMPER
S
ETTING
C
ARRIER
B
OARD
S
IGNAL
phyMAPPER
S
IGNAL
J1
1+2
4+2
3+2
x_/CS_CAN
x_/CS4
x_/CS5
x_/CS3
J2
1+2
4+2
3+2
x_CAN_INT
x_MCU3_2
x_MC2_16
x_MCU2_1
J3
1+2
4+2
3+2
x_TRIGGER
x_MCU3_2
x_/ATA_RESET
x_MCU2_1
J4
1+2
4+2
3+2
x_SNAPSHOT
x_MCU3_3
x_/ATA_DMACK
x_MCU2_2
J5
1+2
4+2
3+2
x_CSI_ENABLE
x_MCU2_3
x_CSI_D5
x_MCU2_0
J6
1+2
4+2
3+2
x_LED
x_MCU2_0
x_MCU3_3
x_GPO1
J7
1+2
4+2
3+2
x_SD_D
x_GPIO1_2
x_GPIO1_25
x_GPIO1_0
J8
1+2
4+2
3+2
x_SD_W
x_GPIO1_3
x_MCU1_26
x_GPIO1_1
J9
1+2
4+2
3+2
x_/IRQ
x_MCU2_1
x_MCU3_1
x_MCU2_2
1 Default settings are in
bold blue
text
Summary of Contents for phyCORE-i.MX31
Page 9: ...Contents PHYTEC Messtechnik GmbH 2007 L 700e_0...
Page 10: ......
Page 55: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 45...
Page 57: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 47...
Page 86: ...phyCOREi MX31 On NOR Flash On NAND Flash 76 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Page 90: ...phyCOREi MX31 80 PHYTEC Messtechnik GmbH 2007 L 700e_0 JP17 more info JP604 more info...
Page 128: ...phyCOREi MX31 118 PHYTEC Messtechnik GmbH 2007 L 700e_0 13 6 1 LCD 004 Physical Dimensions TBD...
Page 135: ...Published by PHYTEC Messtechnik GmbH 2007 Ordering No L 700e_0 Printed in Germany...