kitCON-161CS/JC/JI
26
PHYTEC Meßtechnik GmbH 1999 L-356e_2
4.2
DB9-plug P3 JP2, JP4, JP9
If the kitCON-161CS/JC/JI houses a C161CS or Jx Controller DB9-
plug P3 carries either the CAN-Signals or the signals of the J1850-
Interface. Jumper JP2 and JP9 determine which signals are available
at DB9-plug P3.
Signals at DB9-plug P3
JP2
JP9
CAN1
(S-Controller only)
1+2
3+4
2+3
J1850
(Jx-Controller only)
open
1+2
With jumper JP4 a CAN-bus connected to DB9-plug P3 can be
terminated with a 120
Ω
resistor.
JP4
CAN1 not terminated
open
CAN1 terminated with 120
Ω
resistor
closed
4.3
DB9-plug P2 JP3
With jumper JP3 a CAN-bus connected to DB9-plug P2 can be
terminated with a 120
Ω
resistor.
JP3
CAN0 not terminated
open
CAN0 terminated with 120
Ω
resistor
closed
Summary of Contents for kitCON-161CS
Page 28: ...kitCON 161CS JC JI 22 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 44: ...kitCON 161CS JC JI 38 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 54: ...kitCON 161CS JC JI 48 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 58: ...kitCON 161CS JC JI 52 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 62: ...Published by PHYTEC Me technik GmbH 1999 Ordering No L 356e_2 Printed in Germany...