28
Heater Operation
Starting The Heater
Note:
It is important to understand that this heater does not simply turn on and turn off. Rather, it has a
sophisticated operating system similar to a household furnace to provide reliable heating comfort. The
operator should familiarize themselves with the normal operation of the heater.
Start Up
1. Systems Check Phase
• When switched on, the heater conducts a self check.
• Component integrity (Glow Pin, Blower, Fuel Pump, Flame and Overheat Sensor)
• Voltage (Must be with 10.5-16 volts)
• Upon satisfactory systems check, the heater will continue to the Preheat Phase.
2. Preheat Phase – Glow pin will switch on to preheat for 50 seconds.
3. Ignition Phase – Fuel and combustion air are slowly introduced to the combustion chamber and flame is
established typically within 2-3 seconds.
4. Stabilization Phase – To further establish combustion, the glow pin remains on and the fuel / air mixture
is slowly increased. The flame sensor monitors the increasing temperature at the heat exchanger
(Typically 2 ½ minutes).
5. Running Phase – Once the flame is established, the glow pin will switch off. Incoming fuel / air will be
ignited by the established flame inside the combustion chamber.
Running Mode
The heater is designed to function in two different operating modes. Refer to the Operating Switch
Instructions for details.
“Gear”
mode (Manual) allows you to control the heater output mode in 4 operating levels.
“Automatic Climate -A/C”
mode allows you to control the target cabin temperature that the heater will
maintain. This is the more common operating mode and is practical for use with cargo and cabin heating
applications. This mode allows you to set the target cabin temperature from 8ºC to 36ºC (As measured at the
Control Switch).
Note:
The heater will initially start in “Gear” Mode in the G3 Setting.