14
1.3
Input
/O
ut
put Si
gnal
T
yp
es
FASTCAM Mini AX
14
FASTCA
M Mini
Please refer to “10.6I/O Settings” of “Photron FASTCAM Viewer User’s Manual” for the details of the setup.
•
IRIG Time Code is used when synchronizing a camera with external equipment in time.
It is a convenient function when apparatus is physically separated.
•
When the IRIG code is being input, the IRIG code is displayed in white, and is displayed to the left.
•
The IRIG offset time is also displayed below it. When the IRIG code is not being input, the IRIG code
is displayed in grey. At that time, the counter is the camera’s internal counter and it continues to count.
INPUT(1,2) Connector
The effect when a signal is input is described below, and can be optionally selected and set.
The input voltage is 0V to +12V (H level +3.3V to +12V), positive or negative polarity, pulse width
is 200 ns or greater.
Default settings are INPUT1 connector is assigned “SYNC POS”, INPUT2 connector is assigned
“TRIG POS”.
Menu Display
Contents
Signal
(Input Signal Conditions)
TRIG POS
Inputs a positive polarity trigger signal.
FET Input 0V - +12V
(H level +3.3V to +12V),
Positive Polarity
TRIG NEG
Inputs a negative polarity trigger signal.
FET Input 0V - +12V
(H level +3.3V to +12V),
Negative Polarity
READY POS
Inputs a positive polarity READY signal.
READY ON/OFF is switched by a pulse input.
FET Input 0V - +12V
(H level +3.3V to +12V),
Positive Polarity
READY NEG
Inputs a negative polarity READY signal.
READY ON/OFF is switched by a pulse input.
FET Input 0V - +12V
(H level +3.3V to +12V),
Negative Polarity
EVENT POS
Inputs a positive polarity EVENT signal.
EVENT TRIGGER is recorded by a pulse input.
FET Input 0V - +12V
(H level +3.3V to +12V),
Positive Polarity
EVENT NEG
Inputs a negative polarity EVENT signal.
EVENT TRIGGER is recorded by a pulse input.
FET Input 0V - +12V
(H level +3.3V to +12V),
Negative Polarity
•
When 2 or more these systems are synchronized, slave cameras’ external synchronization settings
should be set “ON CAM” at PFV.
•
The event marker can store ten positions within a sequence.
Summary of Contents for FASTCAM Mini AX Series
Page 1: ...FASTCAM Mini AX Hardware Manual ...
Page 13: ...Contents A 1 3 Relative Spectral Response color 59 A 1 4 Quantum Efficiency color 59 ...
Page 14: ......
Page 39: ...2 Chapter 2 Recording This chapter explains operations related to recording ...
Page 43: ...3 Chapter 3 Product Specifications This chapter explains the system s specifications ...
Page 66: ...52 3 2 Dimensions FASTCAM Mini AX 52 FASTCA AC Power Supply Unit mm ...
Page 67: ...4 3 Chapter 4 Warranty This chapter explains about the warranty ...
Page 71: ...A 3 A Appendix ...