14.6 I/O Connector
14.6.4
Encoder Interface
Fig. 14.6 and Fig. 14.7 show, how differential and single ended encoder must be connected to
the GigE camera’s I/O interface. Encoder A and B singals must be connected to LineIn0 and
LineIn1. They can be connected in either way, as long as the encoder is configured accordingly
Section C.5.
If available on the encoder, the Z signal must be connected to LineIn2 and the Y/ALARM to
LineIn3.
The
EncoderAlarmMode
of the encoder configuration must be set to
True
in order
to use the alarm indication.
Consider the polarity of the encoders Y/ALARM signal. The LineIn3 must be in-
verted, when the Y/ALARM signal is low active.
The Z signal is a single pulse that occurs once every shaft encoder rotation. It can
be used to reset the encoder (Section 7.4).
Isolator
LineIn0
LineIn1
LineIn2
LineIn3
3
4
5
6
7
8
9
2
1
12
11
CAEMRA_PWR
CAMERA_GND
ISO_GND
17
RS422 or D-HTL
TTL120
120
R0
C0
10nF
17-pin M12
I/O Connector
Cam
era
Fi
rmw
are
A
B
Z
ALARM
Encoder
Camera
YOUR_GND
GND
ISO_INC0
R1
C1
ISO_INC1
R2
C2
ISO_INC2
ISO_IN3
Y
Figure 14.6: Connection of a differential encoder
.
MAN093 08/2021 V1.1
107 of 143
Summary of Contents for MV4 Series
Page 8: ...CONTENTS 8 of 143 MAN093 08 2021 V1 1 ...
Page 12: ...1 Preface 12 of 143 MAN093 08 2021 V1 1 ...
Page 40: ...4 Image Acquisition 40 of 143 MAN093 08 2021 V1 1 ...
Page 42: ...5 Exposure Control 42 of 143 MAN093 08 2021 V1 1 ...
Page 52: ...6 Counter Timer 52 of 143 MAN093 08 2021 V1 1 ...
Page 64: ...10 Image Format Control 64 of 143 MAN093 08 2021 V1 1 ...
Page 66: ...11 Frame Rate 66 of 143 MAN093 08 2021 V1 1 ...
Page 82: ...12 Pixel Data Processing 82 of 143 MAN093 08 2021 V1 1 ...
Page 92: ...12 Pixel Data Processing 92 of 143 MAN093 08 2021 V1 1 ...
Page 96: ...13 Precautions 96 of 143 MAN093 08 2021 V1 1 ...
Page 120: ...16 Troubleshooting 120 of 143 MAN093 08 2021 V1 1 ...
Page 126: ...19 Support and Repair 126 of 143 MAN093 08 2021 V1 1 ...
Page 128: ...20 References 128 of 143 MAN093 08 2021 V1 1 ...