5 Counter & Timer
Timer 0 ... 3 Start
Resets with the reception the chosen timer start event.
Timer 0 ... 3 End
Resets with the reception the chosen timer end event.
Software Signal Pulse 0 ... 7
Resets with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Resets when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally a activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Resets with the rising edge on the selected line input.
Falling Edge
Resets with the falling edge on the selected line input
Both Edges
Resets with any edge on the selected line input
Activation configuration has only effect when line input is selected as a counter
reset source, otherwise this configuration is ignored.
5.2
Timer
T
i m
e r
S
o
u
r
c
e
.
.
.
T i m
e r
T r i g g e r
T i m
e r A c t i v e
T i m
e r S t a r t
T i m
e r E n d
T
i m e r V a l u e
T i m e r S t a t u s
T i m e r D e l a y
T i m e r S t a r t V a l u e
T i m e r D u r a t i o n
T i m e r R e s e t ( )
A
c
t
i
v
a
t
i
o
n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
Figure 5.2: Timer Structure
Four general purpose timers are available in the camera (Timer0 ... Timer3). A timer can be
used to generate a timed pulse - for instances a strobe signal - or to generate an event after a
predetermined duration. Each timer can be configured individually by software and controlled
by timer trigger events. This section describes the configuration and the function of the timers.
Fig. 5.2 shows the structure of one timer. It contains a timer trigger source and activation
block. Furthermore it has three output signals: A timer active status signal, which is routed to
the I/O control block (see Chapter 6) and timer start and end event signals, which can be used
to trigger other blocks, like counter, timer, acquisition, frame or exposure control (see Section
5.2.3).
5.2.1
Timer Usage
Timer delay and timer duration value needs to be configured accordingly. When a timer trigger
source is selected the timer is waiting for a trigger signal. Once this trigger signal has been
received, the timer starts first with the timer delay period, if the timer delay value is > 0, and
counts then for the specified timer duration.
40 of 121
MAN076 09/2017 V1.0
Summary of Contents for MV3-D640I-M01-144-CL
Page 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Page 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Page 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Page 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Page 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Page 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Page 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Page 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Page 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Page 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Page 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...