7.1.3
Trigger
This tab contains trigger and strobe settings.
Figure 7.4: MV1-D1312C-160 trigger panel
Trigger
Trigger Source:
Free running:
The camera continuously delivers images with a certain configurable frame rate.
Interface Trigger:
The Trigger signal is applied to the camera by the CameraLink frame grabber
or the USB interface respectively.
I/O Trigger:
The trigger signal is applied directly to the camera on the power supply connector.
Exposure time defined by:
Camera:
The exposure time is defined by the property
ExposureTime
.
Trigger Pulse Width:
The exposure time is defined by the pulse width of the trigger signal
(level-controlled exposure).
This property disables LinLog, Burst trigger and simultaneous readout mode.
Exposure time defined by "Trigger Pulse Width" is also known as Level controlled
trigger.
Further trigger settings:
7.1 MV1-D1312C-160
73
Summary of Contents for MV1-D1312C CameraLink Series
Page 1: ...User Manual MV1 D1312C CameraLink Series CMOS Area Scan Colour Camera MAN046 04 2010 V1 0...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started CameraLink 12...
Page 86: ...7 Graphical User Interface GUI 84...
Page 92: ...9 Warranty 90...
Page 94: ...10 References 92...
Page 98: ...A Pinouts 96...
Page 99: ...B Revision History Revision Date Changes 1 0 March 2010 First release 97...