4 Functionality
4.10.3
Camera Type Codes
Camera Model
Camera Type Code
MV1-D1024E-160-CL-12
110
Table 4.8: Type codes of Photonfocus MV1-D1024E camera series
4.11
Test Images
Test images are generated in the camera FPGA, independent of the image sensor. They can be
used to check the transmission path from the camera to the frame grabber. Independent from
the configured grey level resolution, every possible grey level appears the same number of
times in a test image. Therefore, the histogram of the received image must be flat.
A test image is a useful tool to find data transmission errors that are caused most
often by a defective cable between camera and frame grabber.
The analysis of the test images with a histogram tool gives gives a flat histogram
only if the image width is a multiple of 1024 (in 10 bit or 12 bit mode) or 256 (in
8 bit mode). The height should be a multiple of 1024 In 12 bit mode.
4.11.1
Ramp
Depending on the configured grey level resolution, the ramp test image outputs a constant
pattern with increasing grey level from the left to the right side (see Fig. 4.48).
Figure 4.48: Ramp test images: 8 bit (left), 10 bit (middle), 12 bit (right) at a resolution of 1024x1024 pixels
Implementation details:
8 bit:
Every row has the same data. The leftmost pixel has the value 0 and then the value is
incremented by 1 on every subsequent pixel up to a value of 255. After 255 the next pixel
has the value 0 and the sequence is repeated.
10 bit:
Every row has the same data. The leftmost pixel has the value 0 and then the value is
incremented by 1 on every subsequent pixel up to a value of 1023. After 1023 the next
pixel has the value 0 and the sequence is repeated.
60 of 109
MAN064 02/2020 V1.1
Summary of Contents for MV1-D1024E
Page 6: ...CONTENTS 6 of 109 MAN064 02 2020 V1 1...
Page 10: ...1 Preface 10 of 109 MAN064 02 2020 V1 1...
Page 14: ...2 How to get started CameraLink Figure 2 4 PFRemote start window 14 of 109 MAN064 02 2020 V1 1...
Page 68: ...5 Precautions 68 of 109 MAN064 02 2020 V1 1...
Page 94: ...8 Graphical User Interface GUI 94 of 109 MAN064 02 2020 V1 1...
Page 104: ...12 References 104 of 109 MAN064 02 2020 V1 1...