6.5.6
I/O Wiring
The Photonfocus cameras include electrically isolated inputs and outputs. Take great care when
wiring trigger and strobe signals to the camera, specially over big distances (a few meters) and
in noisy environments. Improper wiring can introduce ground loops which lead to malfunction
of triggers and strobes.
There are two roads to avoid ground loops:
•
Separating I/O ground and power supply (ISO_GND and ISO_PWR) from camera power
(CAM_GND, CAM_PWR)
•
Using a common power supply for camera and I/O signals with star-wiring
Separate Grounds
To separate the signal and ground connections of the camera (CAM_GND, CAM_PWR, data
connections) from the I/O connections (ISO_GND, ISO_PWR, ISO_IN, ISO_OUT) is one way to
avoid ground loops. Fig. 6.13 shows a schematic of this setup. In this setup the power supplies
for the camera and for ISO power must be separate devices.
I
s o l a t o r
C A M _ G N D
I S O _ I N
I S O _ G N D
G r o u n d p l a n e v o l t a g e d i f f e r e n c e
I S O _ G N D
S e p a r a t e g r o u n d
n o g r o u n d l o o p
Figure 6.13: I/O wiring using separate ground
.
6.5 Trigger and Strobe Signals for GigE Cameras
87
Summary of Contents for DR1-D3360-192-G2-8
Page 1: ...MAN071 03 2015 V1 0 Photonfocus MV1 D3360 G2 Camera Series CMOS camera with GigE interface...
Page 10: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 10...
Page 22: ...4 Product Speci cation Figure 4 1 Photonfocus D3360 GigE camera series with C mount lens 22...
Page 76: ...5 Functionality 76...
Page 92: ...6 Hardware Interface 92...
Page 112: ...9 Warranty 112...
Page 114: ...10 References 114...
Page 119: ...C Document Revision History Revision Date Changes 1 0 March 2016 First version 119...