General note
Please follow below instructions step by step. For more
detailed information or troubleshooting, please refer to the
User Manual (see CD-ROM). We recommend you to read
the User Manual to fully understand the system. Latest
versions of all documents can be downloaded on
www.phonomation.com
.
INSTALLATION IN 8 STEPS
1. Check of contents
Please unpack carefully and check all items:
1
phonomator
®
1
mains cable
8
cable glands
1
documentation CD
1
quick installation guide
1
list of factory setting
1
drill template
4
screws and wall plugs
2. Mounting
Define the mounting position of the
phonomator
®
on
a planar wall.
Use a mobile phone to make sure that mobile phone
operation is possible in the chosen location.
A 230 VAC electric outlet must be within suitable distance
to plug in the provided power cable. Do not plug in the
plug yet!
Use the drill template when fixing your
phonomator
®
with the 4 provided wall plugs and screws.
3. Connect cables
Knock out 4 cable entries (see picture 2):
●
The 2
nd
on the right for mains power.
●
The 3
rd
on the right for motor cable.
●
The 2
nd
on the left for lower photocell.
●
The 3
rd
on the left for safety edge (with pre-limit
switch)
Mount 4 (or as much as you need for your application) of
the cable glands provided (see picture 2).
Connect cables (see picture 3 und 4).
CAUTION!
Electrical installation must only be
carried out by a qualified electrician!
picture
2 :
Mounting position of cable glands
picture
4 :
Connection of a lower
photocell and a safety edge with pre-
limit switch
Connecting the power input of the
photocell to terminal 3 (+12V) and 4
(SWGND= switched ground) allows
for selftesting of the photocell each
time the door will start to close.
picture
1 :
Main function of operating elements
Note: Colour of LED can only be seen when activated.
phonomator
®
This quick guide contains
important information Please
make sure to pass on this
document to the end-user
after installation.
QUICK INSTALLATION GUIDE
picture
3 :
230VAC connections
MAINS
Terminal 1: PE
prot. earth
Terminal 2: L
230V phase
Terminal 3: N
230V neutral
MOTOR
Terminal 6: PE
prot. earth
Terminal 7: N
MO
neutral
Terminal 8: L
O
phase/
↑
Terminal 9:
L
C
phase/
↓
Version 3.
1