Phonic MAX 3500 User Manual Download Page 5

1

English           

  

MAX 3500

INTRODUCTION

Congratulations on your purchase of the MAX 3500 
power  amplifier.  Based  on  years  of  experience  in 
designing and manufacturing professional audio 
equipment, we at Phonic designed this power am-
plifier  for  those  who  need  an  extremely  powerful, 
reliable and sturdy amplifier. Taking advantage of its 
huge heat sink as well as its variable speed fan that 
auto-adjusts fan speed depending on the tempera-
ture of the machine during operation, MAX power 
amps are always able to perform. Its professional 
quality output and its sturdy case design make this 
unit great for various locations like churches, concert 
tours, stages, disco, pubs, or any place that requires 
amplifier installation. 

This unit is designed with great care and great atten-
tion to details, so please read this manual carefully. 
Look after it and keep it in a safe place for future 
reference.

FEATURES

4

2400 Watts per channel at 4 ohms with a 3U 

footprint

4

High current toroidal transformer allowing high 

power output with low noise and low distortion

4

Built in limiter with a button allowing user to disable 

limiter’s function

4

Balanced XLR inputs

4

Grounding/Floating switch to avoid grounding 

loop

4

Binding post and speakon-type outputs

4

Front mounted gain controls for easy access

4

Signal  and  Peak  LED  indicators  to  monitor  per-

formance

4

Protection: short circuit, thermal, subsonic, RF 

protection, output DC offset, power on/off muting

GETTING STARTED

1. 

Check  the AC  voltage  before  connecting  the 
power plug to the outlet. Make sure the AC power 
supply shares the same voltage used in your 
country (For example, while some countries use 
100V, others use 120V, 230V, or 240V). Please 
ensure your device is properly grounded.

2.

 Before turning on the power, make sure the gain 

controls are turned all the way down to prevent 
other equipment from harm.

3.

 Check your cables regularly and label each end 

clearly for easy identification.

4.

 Always turn the power off before connecting to 

and disconnecting from the unit.

5.

 NEVER use solvents to clean the unit. Clean it 

with a soft and damp or dry cloth.

INSTALLATION

MOUNTING THE UNIT

Designed  to  fit  into  a  standard  19-inch  rack,  this 
unit only takes up 3 units of rack space. Secure this 
unit with 4 rack-mount screws and cup washers. In 
general, power amplifiers usually are heavier than 
any other audio equipment, so when installing this 
unit onto a rack, begin placing it from the bottom of 
the rack. We advise leaving one rack-space between 
power amplifiers and other devices to guarantee bet-
ter cooling (see figure 1).

Figure 1  Rack Mount

Summary of Contents for MAX 3500

Page 1: ...User s Manual Manual del Usuario MAX 3500...

Page 2: ...POWER AMPLIFIER AMPLIFICADOR POTENCIADO MAX 3500 English Espa ol ENGLISH I ESPA OL II V1 1 09 25 2012...

Page 3: ...1 FEATURES 1 GETTING STARTED 1 INSTALLATION 1 CONNECTIONS 2 OPERATION 3 PROTECTION 6 SPECIFICATIONS 7 CONTENTS USER S MANUAL Phonic preserves the right to improve or alter any information within this...

Page 4: ...uring lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord...

Page 5: ...ing loop 4Binding post and speakon type outputs 4Front mounted gain controls for easy access 4Signal and Peak LED indicators to monitor per formance 4Protection short circuit thermal subsonic RF prote...

Page 6: ...Binding posts and speakon connectors make up the unit s output section Loudspeakers can easily be connected using banana plugs spade lugs bare wires or speakon connector More people prefer using spea...

Page 7: ...ED to go on 8 Gain Controls These two rotary knobs control the signal level of the in put These center detented controls allow precise volume setting Slowly turn the knob clockwise to increase input l...

Page 8: ...TEREO STEREO mode is the most frequently used mode among the three Each channel is independent of the other carrying its own input signal with its own gain control Stereo mode comes in left and right...

Page 9: ...g speakon treat PIN 1 as the and PIN 2 as the when using binding posts treat Channel 1 as the and Channel 2 as the Do not use Channel 2 s speakon output in this mode When bridge mono the gain control...

Page 10: ...variable speed fan that auto adjusts speed depending on the temperature of the machine during operation However for some reason the unit could not effectively vent out excessive heat this feature wou...

Page 11: ...ont panel AC power switch Gain knobs Rear panel HPF Clip Limiter Operating Mode Circuit Breaker Grounding Floating Operating Modes Parallel Stereo Bridge Mono Voltage Gain 40 x 32 dB Connectors each c...

Page 12: ...f the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorization In order to keep this warranty in e...

Page 13: ...ario Phonic se reserva el derecho de mejorar o alterar cualquier informaci n provista dentro de este documento sin previo aviso INTRODUCCI N 1 CARACTER STICAS 1 INICIANDO 1 INSTALACI N 1 CONEXIONES 2...

Page 14: ...10 MAX 3500 Espa ol...

Page 15: ...ding Floating para evitar bucle de a tierra Borne y salidas tipo conector de caja ac stica speakon Control de montaje de ganancia frontal para acceso f cil Indicadores de Se al y Pico LED para monitor...

Page 16: ...ser f cilmente conectadas usando el conector circular macho spade lugs electrodo desnudo o conectores de cajas ac stica speakon La mayor a de la gente prefiere usar conectores de cajas ac sticas m s...

Page 17: ...dos perillas giratorios controla el nivel de se al de entrada Este centro de control de distensi n permite precisar la configuraci n del volumen Lentamente encienda el pomo girando a la derecha para i...

Page 18: ...do de estos tres modos Cada canal es independiente del otro llevando su propia se al de entrada con su propio control de ganancia El modo Estereo viene en los canales de derecha e izquierda Ver ilustr...

Page 19: ...e Y cuando se el conector de caja ac stica speakon trate con PIN1 como y PIN2 es Tambi n al usar el borne trata al canal 1 como y el canal2 como No usar el modo de salida del canal 2 de speakon cuando...

Page 20: ...pendiendo de la temperatura de la maquina durante la operaci n Sin embargo si por alguna raz n la unidad no pueda majenar efectivamente el exceso de aire calido esta caracter stica puede proteger la u...

Page 21: ...ganancias Panel Posterior HPF Clip Limitador Modo Operativo Disyun tor de circuito Grounding Floating Modos Operativos Paralelo Estereo Puente Mono Ganancias de Voltaje 40 x 32 dB Conectores Para cada...

Page 22: ...a fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado return merchandise autorization En orden d...

Page 23: ......

Page 24: ......

Reviews: