background image

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not 

fit

 into your outlet, consult 

an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

specified

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

specified

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

qualified

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK

)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

s enclosure that may be of sufficient

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance 

(servicing)

 instructions in the literature 

accompanying the appliance.

WARNING: 

To reduce the risk of 

fire

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

specified

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

filled

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

confined

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for DYN2000

Page 1: ...DYN2000 DYNAMIC PROCESSOR English User s Manual...

Page 2: ...or when unused for long periods of time 14 Refer all servicing to quali ed service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is...

Page 3: ...suppied within this document without prior notice V1 2 NOV 12 2007 TABLE OF CONTENTS INTRODUCTION 4 FEATURES 4 QUICK SETUP 4 FRONT PANEL DESCRIPTION 5 Expander Gate Section 5 Compressor Section 5 Mas...

Page 4: ...s total control of maximum peak levels at the output regardless of any other control System bypass buttons on both channels useful for comparing processed and unprocessed signals 8 Segment LED display...

Page 5: ...ng to eliminate residual noise often associated with gating 2 Sidechain Enable Button This switch enables the sidechain allowing users to use the 1 4 TRS sidechain connector on the rear of the DYN2000...

Page 6: ...soft knee style of compression is used basically easing into the compression just prior to hitting the threshold 9 Ratio Control This allows users to adjust the ratio between the input signal receive...

Page 7: ...to the unit is off While using the unit however the bypass is useful in comparing processed and unprocessed signals 15 Output Level Meter This 5 segment level meter gives users a visual indication of...

Page 8: ...channel between 10 dBV consumer level and 4 dBu professional level 21 Sidechain Insert Points This 1 4 TRS connector allows users to send and receive signals to and from external processors using a sp...

Page 9: ...ly 0 08 10dBu 15dB Gain reduction COMPRESSION Threshold Range 40dBu to 20dBu Threshold Characteristic Selectable easy or hard knee Compression Ratio Variable 1 1 to Infinity 1 60dB Maximum Compression...

Page 10: ...10 DYN2000 DIMENSIONS 482 19 44 1 7 183 7 2 All measurements are shown in mm inches...

Page 11: ...11 DYN2000 BLOCK DIAGRAM...

Page 12: ...original date of purchase against defects in material and workman ship under use as instructed by the user s manual Phonic at its option shall repair or replace the defective unit covered by this war...

Page 13: ......

Reviews: