background image

21

Warranty limitation

This warranty does not cover damage from improper 
handling or care, exposure to chemicals or undue stress. 
Damage caused by third parties or non-authorized service 
centers renders the warranty null and void. This warranty 
does not include any services performed by a hearing care 
professional in their office.

Serial number:

Date of purchase:

Authorized hearing care 
professional (stamp/signature):

Summary of Contents for Naida Link CROS

Page 1: ...User Guide Phonak Na da Link CROS...

Page 2: ...da Link CROS CE mark applied 2017 This user guide is valid for This user guide only applies to the CROS device Please see the AB Na da CI sound processor user guide for instructions related to the AB...

Page 3: ...3 Your CROS device Model Na da Link CROS Earpiece c Dome c CROS Tip Battery type 13...

Page 4: ...d is designed to keep you connected to the beauty of sound We thank you for making such a great choice and wish you many years of listening pleasure Please read the User Guide carefully to make sure t...

Page 5: ...ngs 4 On Off 5 Batteries 6 Putting on the CROS device 7 Removing the CROS device 8 Push button Further Information 9 Care and maintenance 10 Service and warranty 11 Compliance information 12 Informati...

Page 6: ...gs Changing batteries 1 2 3 Blue marking for left device Red marking for right device Remove the sticker from the new battery and wait two minutes Open the battery door Place battery in the battery do...

Page 7: ...7 On Off Push button The push button on your device functions as a mute button to mute the sound delivered from the CROS device Off On...

Page 8: ...th the AB Na da CI sound processor on the other ear Na da Link CROS transfers the microphone input signal to the AB Na da CI sound processor The sound processor receives the signal and makes sounds fr...

Page 9: ...9 Possible earpieces for the Na da Link CROS device CROS Tip Push button Na da Link CROS Tube Removal handle Battery door Dome CROS Tip...

Page 10: ...10 3 Left right CROS device markings There is a red or blue marking to tell you if it is a left or a right device Blue marking for left device Red marking for right device...

Page 11: ...11 4 On Off The battery door is also the on off switch 1 2 Closed battery door CROS device is on Open battery door CROS device is off...

Page 12: ...y in the battery door with the symbol facing upwards If it is difficult to close the battery door Check that the battery is inserted correctly and the symbol is facing the label inside the battery com...

Page 13: ...on package orange IEC code PR48 ANSI code 7000ZD Replacement battery This CROS device requires zinc air batteries Please ensure you use the correct type of battery in your CROS device zinc air Please...

Page 14: ...on the CROS device 1 2 3 Place the CROS device behind your ear Insert the earpiece into your ear canal If there is an anchor attached to the earpiece tuck it into the bowl of your ear to secure your...

Page 15: ...CROS device from behind the ear In very rare cases your earpiece can remain in your ear canal when removing the device from the ear In the unlikely case that the earpiece does get stuck in your ear ca...

Page 16: ...16 8 Push button The push button on your CROS device functions as a mute button to mute the sound delivered from the CROS device...

Page 17: ...2 General information Before using hair spray or applying cosmetics you should remove your CROS device from your ear because these products may damage it When you are not using your CROS device leave...

Page 18: ...ter sweat or dust the device is cleaned and dried The CROS device is used and maintained as described in this user guide Use of your CROS device around water can restrict air flow to the batteries cau...

Page 19: ...ed to clean your CROS device intensively ask your hearing care professional for advice and information on drying capsules Weekly Clean the earpiece with a soft damp cloth or with a special cleaning cl...

Page 20: ...onal warranty valid from the date of purchase This limited warranty covers manufacturing and material defects in the CROS device itself but not accessories such as batteries tubes earmolds external re...

Page 21: ...icals or undue stress Damage caused by third parties or non authorized service centers renders the warranty null and void This warranty does not include any services performed by a hearing care profes...

Page 22: ...or the local Phonak representative whose address can be taken from the list on www phonak com Phonak worldwide locations 11 Compliance information Australia New Zealand Indicates a device s complianc...

Page 23: ...23 The wireless model listed on page 2 is certified under Phonak Na da Link CROS USA FCC ID KWC NLCROS Canada IC 2262A NLCROS...

Page 24: ...made to this device not expressly approved by Sonova AG may void the FCC authorization to operate this device Notice 3 This device has been tested and found to comply with the limits for a Class B dig...

Page 25: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incre...

Page 26: ...U The numbers after the CE symbol correspond to the code of certified institutions that were consulted under the above mentioned directives This symbol indicates that the products described in these u...

Page 27: ...rtant for the user to pay attention to the relevant warning notices in these user guides Important information for handling and product safety The product is designed such that it functions without pr...

Page 28: ...not in use See instruction in chapter 15 2 regarding drying the device after use Atmospheric pressure 200 hPA to 1500 hPa The symbol with the crossed out garbage bin is to make you aware that this de...

Page 29: ...29...

Page 30: ...earing care professional for assistance Causes Dead battery Battery not inserted correctly CROS device switched off CROS device in mute mode CROS device out of range of AB sound processor Problem CROS...

Page 31: ...chapter 1 5 Switch CROS device on by completely closing the battery door chapter 4 Press push button on the CROS device to so that the sound is no longer muted chapter 8 Place CROS device within rang...

Page 32: ...nd will not prevent or improve a hearing impairment resulting from organic conditions Infrequent use does not permit a user to attain full benefit from it The use of a CROS device is only part of hear...

Page 33: ...are not permitted Such changes may damage your ear or the CROS device Do not use the CROS device in explosive areas mines or industrial areas with danger of explosions oxygen rich environments or area...

Page 34: ...t stuck in your ear canal it is strongly recommended to see a physician for safe removal Hearing programs in the directional microphone mode reduce background noises Please be aware that warning signa...

Page 35: ...ny interference do not use the CROS device and contact the manufacturer of the active implant Please note that interference can also be caused by power lines electrostatic discharge airport metal dete...

Page 36: ...ystems when used by clients with perforated eardrums inflamed ear canals or otherwise exposed middle ear cavities In the unlikely case that any part of this product should remain in the ear canal it i...

Page 37: ...ting devices to dry your CROS device Ask your hearing care professional about suitable drying methods 14 2 Information on product safety The dome should be changed every three months or when it become...

Page 38: ...tion You can return used batteries to your hearing care professional The batteries used in the CROS device should not exceed 1 5 Volts Please do not use silver zinc or lithium ion rechargeable batteri...

Page 39: ...keep them outside the examination room area before undergoing Medical or dental examination with X ray also CT scan Medical examinations with MRI NMRI scans generating magnetic fields CROS devices do...

Page 40: ...Manufacturer Sonova AG Laubisr tistrasse 28 CH 8712 St fa Switzerland www phonak com 029 0486 02 V2 00 2017 06 FO Sonova AG All rights reserved Your hearing care professional...

Reviews: