background image

8/13 

4. Super code functions

The super code is preset from the factory at

 (7x1). It can open the lock and 

reset the opening code.  

4.1 Change super code  

The super code can be changed with the opening code. 

 In opened lock condition 

Button 

Signal 

Description 

 3sec 

Start programming 

Code 

 

 

 

 

 

 

Enter new super code 

 

 

 

 

 

 

Repeat new super code 

Changed 

Error 

  The super code is not a regular opening code and is only intended for emergencies. The factory 

setting must be changed for security reasons. Even if it is only used in exceptional cases and is 
therefore difficult to remember, this code may not be written down. 

1  1  1  1  1  1  1 

DS4650 Millenium Duplex Instructions

Summary of Contents for Solar

Page 1: ... Phoenix Safe Company Ltd V1 AUG 2017 SOLAR Basic Operating instructions for electronic high security locks DS4650 Millenium Duplex Instructions ...

Page 2: ... description 4 1 Opening Closing 5 2 Changing the code 6 3 Retrieve opening protocol 7 4 Super code functions 8 5 Power supply 10 6 Restart 11 7 Signal table 11 8 Technical data and certification 12 9 Quick guide SOLAR Basic 13 DS4650 Millenium Duplex Instructions ...

Page 3: ...n The following codes are preset from the factory and must be changed for security reasons Perform all changes only with the door open and the locking mechanism closed bolts extend from the door Code Opening code 1 2 3 4 5 6 SUPER 1 1 1 1 1 1 1 Function and use of the super code see item 4 The lock must first be opened to change the settings The lock is locked and unlocked by a motor When the moto...

Page 4: ...ve minutes which can be seen by the 8 second blinking interval of the red LED If an incorrect entry is again made after the duration of the blocking period the five minute blocking period begins once more This is only overridden by the entry of a valid code Emergency power If the battery is completely discharged and the lock can no longer be opened the lock can be supplied with power externally Fo...

Page 5: ...edure can be repeated three times Then a blocking period of 5 minutes goes into effect manipulation block 1 2 Closing Ensure that the handle of the locking mechanism is completely in the closed position Button example Signal Description Closing 3sec Closed After pressing the button the handle of the locking mechanism may not be pulled until the lock has locked After locking you must check whether ...

Page 6: ...r In case of a long acoustic signal the code has not been changed due to an incorrect entry The old code is still active You must repeat the procedure After successfully changing the code the new code must be tested by opening and closing numerous times with the door open and the locking mechanism closed For security reasons set codes should not be written down 1 2 3 4 5 6 DS4650 Millenium Duplex ...

Page 7: ... and optical signals in accordance with the table below The latest event is output first In opened lock condition Button Signal Description 3sec Start programming Code Start output Confirm and start Signal Description Signal Description 1x User 3x Mechanical blocking 2x Super code 4x Battery low voltage 1x Separates users events 1 2 3 4 5 6 4 DS4650 Millenium Duplex Instructions ...

Page 8: ...tton Signal Description 3sec Start programming Code Enter new super code Repeat new super code Changed Error The super code is not a regular opening code and is only intended for emergencies The factory setting must be changed for security reasons Even if it is only used in exceptional cases and is therefore difficult to remember this code may not be written down 1 1 1 1 1 1 1 1 2 3 4 5 6 DS4650 M...

Page 9: ... Resetting the opening code by means of the super code If the opening code is lost this can be reset with the super code In opened lock condition Button Signal Description 6sec 3sec 3sec Start reset Super code Super code Confirm and close Changed Error After a successful reset the opening code is set to and must now be changed again 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 DS4650 ...

Page 10: ...ly prying with a flat dull screwdriver on the edge of the keypad between 4 and 7 above the LED and between 6 and 9 2 Pull the keypad out approximately 5 cm with both cables and lift it 3 Clip the new 9V battery into the two poles large to small small to large on the back Here provide support with your fingers on the front of the keypad between 0 and 9 4 Now proceed in accordance with the operating...

Page 11: ...try 1 x x x Star button at the beginning of programming 3 x x x Star button at the beginning of super code entry 3 x x x Functions of the system monitoring Battery dead 1 x x x Lock opens as long as the motor runs x Lock open 1 x x x Lock closes as long as the motor runs x Lock closed 1 x x x Motor mechanically blocked 2 x x x Start of the manipulation block 3 x x x Functions of the manipulation b...

Page 12: ...al min 3V with a load of 0 5A max 12 V at all load levels Batteries 9V alkaline or lithium block battery Useful life of the battery in normal operation approximately 2 years Maximum locking force 25 N Lock class II B approval number M103343 Tested by VdS Köln in accordance with VdS 2344 2005 12 VdS 2841 2005 12 and EN 1300 2004 06 DS4650 Millenium Duplex Instructions ...

Page 13: ...13 13 9 Quick guide SOLAR Basic 3sec 3sec 3sec 3sec 1 2 3 4 5 6 C 1 2 3 4 5 6 1 2 6 5 4 3 1 2 3 4 5 6 1 2 3 4 5 6 DS4650 Millenium Duplex Instructions ...

Reviews: