Chapter 3 Command Descriptions
113
set expander-fault-isolation
Description
When fault isolation is enabled, the expander controller will isolate PHYs that fail
to meet certain criteria. When fault isolation is disabled, the errors are noted in the
logs but the PHYs are not isolated.
Input
Example
Enable checking of the PHYs on both controllers at WWPN
500C0FF0ABCD343C.
Related Commands
Q
“set expander-phy” on page 114
Q
“show expander-status” on page 165
Q
“show enclosure-status” on page 158
set expander-fault-isolation wwn
enclosure
[controller a|b|both]
enable|disable
Parameter
Description
wwn
enclosure
Specifies the 16-hex-digit logical identifier of the
controller enclosure or expansion enclosure containing
the PHY to be enabled or disabled. The enclosure
logical identifier is found in the WWPN field in the
output of the
show enclosure-status
command.
c
ontroller a|b|both
Optional. Specifies whether the expander is connected
to controller A (upper), controller B (lower), or both.
enable|disable
Specifies whether to enable or disable the PHY in the
SAS expander(s).
# set expander-fault-isolation wwn 500C0FF0ABCD343C controller
both enable
Summary of Contents for RPC12 Series
Page 1: ......
Page 11: ...12 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 29: ...30 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 35: ...36 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 227: ...228 Phoenix RPC12 Series CLI Reference Manual September 2008...