background image

3

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

3 Operating Instructions

The speed, movement and directional controls are located 
on the control box at the top of the handle assembly.

3.1 Steering

To steer the Hydro-X Xtreme Xtractor, remove the middle 
hitch pin on the wheel/base assembly. When finished 
extracting, moving or transporting the Hydro-X, be sure the 
reinstall to hitch pin.

3.2 Directional Control

Select the “Forward” or “Reverse” switch to set the 
desired direction of movement. When the Forward/Reverse 
switch is in either movement position, the machine will 
begin motion when the handle on the handle grip is 
depressed.

3.3 Movement Control

Depress the handle on the left handle grip to begin 
movement. Always start movement on the Hydro-X with the 
speed control set to “Slow.” Depressing the movement 
handle when the Hydro-X speed control is set to “Fast” 
may cause the operator to lose their balance as the 
machine will start moving quickly. Before changing from 
Forward to Reverse or vice versa, release the motion 
handle.

3.4 Speed Control

The knob marked “Fast/Slow” controls the speed of 
movement from 1 to 28 feet per minute. Recommended 
speed for extracting water from berber is slow. 
Recommended speed for cut pile is fast.

4 Basic Extraction Technique

If there is more than 1” of standing water in the area to be  
extracted, a sump pump should be used to remove standing 
water. 

Start in corner of room - extract one pass forward and one 
pass back. Pull corner of carpet back to inspect pad. If 
no water splashes when jumped on with foot, two passes 
are sufficient for extraction. If there is water splash, make 
another pass and re-check. After determining the number 
of passes required, extract entire room.

5 Other Information

5.1 Vacuum Units 

For maximum extraction, the recommended vacuum unit is 
the Phoenix Hydro-X Vacuum Pac. However, if using a truck 
mounted vacuum unit, a 2” hose must be used from truck 
to the Phoenix Hydro-X Xtreme Xtractor. Using a portable 
vacuum unit other than the Phoenix Hydro-X Vacuum Pac is 
not recommended.

5.2 Troubleshooting

This chart suggests common answers to problems with 
your Hydro-X. The information is not all-inclusive and does 
not necessarily apply in all cases. If unusual operating 
conditions, or other problems occur, obtain technical 
assistance from the manufacturer.
If the unit fails to operate:

No Power

 - Check home circuit breakers or receptacle with 

circuit tester.

Blown Fuse or Open Breaker

 - Replace fuses or reset 

circuit breaker. Inspect for damaged wiring.

GFCI Tripped

 - After plugging in GFCI and machine 

power cord, press “RESET” button on GFCI.

Loose Motor Connections

 - Check handle to motor lead 

connection.

Figure 2: Remove 
the hitch pin to 
steer the Hydro-X 
during extraction

Figure 3: Directional controls 
feature forward, reverse 
and off. In the “off” setting 
the Hydro-X will not move 
when the movement lever is 
depressed.

Figure 4: Compress 
the movement handle 
when ready to begin 
extraction.

Figure 5: The Hydro-X 
can move from 1 to 
28 feet per minute 
with the use of the 
speed control knob.

Reviews: