Table of Contents

Introduction

 .............................................................................1

1.  Specifications

 ..................................................................2

2.  Important Safety Instructions

 ........................................2

3. Operation

 .........................................................................2

 

3.1 Transporting the Phoenix AirMax .............................2

 

3.2 Electrical Requirements ............................................2

 

3.3 Ducting .......................................................................2

 

 3.4 Resettable Circuit Breaker .......................................3

 

3.5 GFCI Protection and On-Board Duplex Receptacle .3

4. Maintenance

 ....................................................................3

 

4.1 Power Cord .................................................................3

 

4.2 Cleaning .....................................................................3

 

4.3 Service .......................................................................3

5.  Wiring Diagram

 ...............................................................4

6.  Service Parts

 ....................................................................5

 Warranty

 ...........................................................................6

Serial No.__________________________________
 
Purchase Date_____________________________

Dealer’s Name_____________________________

Read the operation and maintenance instructions carefully 

before using this unit. Proper adherence to these instructions 

is essential to obtain maximum benefit from your Phoenix 

AirMax.

1 Specifications

Part No.

 

4035000

Power

 

110-120 VAC, 1.9 Amps

Blower

 

925 CFM

Cord 

20ft 6in Power Cord

Warranty

 

One Year, 100% Parts and Labor

Dimensions 

Width 17” 

 

Height   

8 7/8” 

 

Depth 

20 1/2”  

 

Weight 

21 lbs. 

2 Important Safety Instructions

CAUTION: Risk of electric shock.  Can cause injury or death 
to reduce the risk of electric shock:
•  Do not expose to standing water or rain
•  Do not use an extension cord
•  Unplug fan before servicing.
•  Do not block air intake or outlet.  One foot minimum 

distance to obstructions.

            Indoor use only

•  Do not use as stool or bench
•  Do not operate with damaged cord or plug.
•  Do not run cord under carpeting. Do not cover cord with 

throw rugs, runners, or similar coverings. Do not route 
cord under furniture or appliances. Arrange cord away 
from traffic area and where it will not be tripped over.

WARNING: Not Suitable for use with Solid-State Speed 

Controls
AVERTISSEMENT: Ne Convient Pas a Des Regulateurs De 
Vitesse a Semi-Conducteurs

 
3 Operation

3.1 Transporting the Phoenix AirMax

The Phoenix AirMax is designed to be stacked vertically or 

horizontally (“Bookshelf Stacking”) for transport.

 
3.2 Electrical Requirements

The Phoenix AirMax can be plugged directly into any standard 

wall receptacle.  Without ducting, the Phoenix AirMax will 

draw 1.9 amps at 120 VAC. Ducting will reduce amp draw. Up 

to 6 Phoenix AirMaxs can be daisy chained on a standard 15 

amp branch circuit.

 

Summary of Contents for AirMax

Page 1: ...This gives you high velocity air over a 25 larger area than other low profile air movers In addition the Phoenix AirMax is stable on all 5 sides for maximum flexibility to position and direct the drying The Phoenix AirMax is the safest fan in its class providing a quality GFCI convenience receptacle that protects not only connected loads but onboard components as well This is unlike competing fans...

Page 2: ...tant Safety Instructions CAUTION Risk of electric shock Can cause injury or death to reduce the risk of electric shock Do not expose to standing water or rain Do not use an extension cord Unplug fan before servicing Do not block air intake or outlet One foot minimum distance to obstructions Indoor use only Do not use as stool or bench Do not operate with damaged cord or plug Do not run cord under ...

Page 3: ...rly the RESET button will pop out In addition notice that the fan will NOT operate if the GFCI outlet is in the TRIPPED condition as the motor and other on board components are included in the GFCI protected circuit The GFCI circuit can only be RESET when the Phoenix AirMax is connected to a properly grounded wall outlet providing the rated voltage 4 Maintenance WARNING Disconnect the unit from po...

Page 4: ...ix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram HOT NEUTRAL LOAD LINE GFCI DUPLEX YEL GROUNDED PLUG WHT BLK WHT BLK POWER SWITCH BRN PUR FAN MOTOR 12 AMP CIRCUIT BREAKER 20 µF CAPACITOR PUR PUR ...

Page 5: ...ion 4035662 Impeller Assembly 4036557 Power Cord Kit 20 cord bolts nuts 4035235 08 Run Capacitor 20 mfd 370 VAC 4035665 Rubber Feet 4036256 Duplex GFCI Outlet Kit 4035825 Rocker Switch 4035752 12A Circuit Breaker 4037469 Inlet Grill 4036486 20 Cord Only Optional Parts 4024936 Duct Lay Flat 14 x 250 ...

Page 6: ...6 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank ...

Page 7: ...ir or installation accident acts of nature or any other cause beyond Therma Stor Products reasonable control Limitations and Exclusions If any AirMax Fan part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by the period of time if any that the AirMax Fan is out of service wh...