![background image](http://html.mh-extra.com/html/phoenix/4030940/4030940_installation-operation-and-service-instructions_1551209005.webp)
5
www.UsePhoenix.com • [email protected]
Toll-Free 1-800-533-7533 or 1-608-237-8400
Figure 9: 50Hz Axial Air Mover Operator Panel
8 Operator Panel Features
8.1 Run-Time Hour Meter
The operator interface panel is equipped with an Automatic
LCD (Liquid Crystal Display) Hour meter. This hour meter
displays cumulative run time. The hour meter meets IP65
for moisture and dust protection and is designed to survive
harsh restoration and water recovery applications. The hour
meter features non-volatile eeProm memory. This type of
memory cannot be erased, nor reset. This feature ensures
accurate time tracking.
The display can be used to track time-of-operation and time-
to-dry. Some restoration professionals use the hour meters to
help them establish billable hours.
8.2 Power Indication Lamp
The red, sealed, high intensity AC voltage power indication
lamp allows operators to visually identify the operation status
of several Phoenix 50Hz Axial Air Movers at a distance, with a
single glance. The power indication lamp will remain lit when
the AC power cord is plugged into a standard “powered”
AC power outlet and the 3-position drying selector switch
is in either the HIGH or LOW operation position. The power
indication lamp will remain unlit when the AC power cord is
unplugged, the 3-position drying selector switch in the OFF
position, or the connected, standard AC wall outlet power has
been turned off.
8.3 3-Position Drying Selector Switch
The 3-position drying mode selector switch. This switch is
used to select the Phoenix 50Hz Axial Air Mover’s mode of
operation. The 3 modes of operation are OFF, LOW or HIGH.
9 Maintenance
WARNING: Disconnect the unit from power before servicing
or cleaning. Replace the wire safety grill after
servicing or cleaning.
9.1 Servicing
Before each use inspect for damage, blocked inlet or outlet,
or any excess buildup of foreign material.
When the Phoenix 50Hz Axial Air Mover is first turned on,
check for excessive vibration. If the unit vibrates excessively
or if blade rubs on housing, turn off the unit immediately.
Have a service technician inspect the unit to locate the
problem.
9.2 Cleaning
The housing is made of a durable and washable polyethylene.
When cleaning, the use of solvents is NOT recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the operator interface panel with a
cloth. Clean inner barrel, grills and blade. Wipe down motor
exterior with a damp cloth. If the motor gets wet during
cleaning, simply allow ample time for motor to dry out
completely before restarting.
If you wash the 50Hz Axial Air Mover and do not plan to use it
within 24 hours, allow the fan to drip dry for 10 minutes and
then let run for 5 minutes.
Hour Meter
3-Position
Selector Switch
Power
Indication
Lamp