background image

DAISY CHAINING

Every Quattro3 comes with the built-in ability to connect to other Quattro3s (up to 15 units). 
This feature enables you to provide coverage for larger spaces using a chain of Q3s.

MAKING THE CONNECTION:

Choose the unit you wish to act as the master unit. This unit will be the one interfacing for 
the entire chain (i.e. telephone interface). The master unit will be the only unit connected to 
an external device, while the other units will connect only to each other.

Using either the provided daisy chain cable or any other Ethernet cable, connect one of the 
cable ends to the master unit’s daisy chain DOWN connector (the RJ45 connector marked 
DOWN). Take the other end of the cable and connect it to the next Quattro3’s daisy chain UP 
connector (the RJ45 connector marked UP). Repeat the process in order to connect a third 
unit to unit number 2. This process can be repeated with up to 15 units regardless of their 
interface type. All units in the chain must be Quattro3s.

POWERING THE DAISY CHAIN:

Every unit in the chain must be powered. In order to do this, there are two available options:
•   Power each unit separately, using its own provided USB cable, DC power supply, or internal  
     battery (if applicable).
•   Power only the master unit using the “Daisy Chain Power Kit”. This setup will require you 
     to connect only the first unit to a power source and will allow the rest of the units to feed
     off the master unit via the Ethernet daisy chain cables.

NOTE:

 The “Daisy Chain Power Kit” utilizes a 48V power supply not included with the 

Quattro3 and must be purchased separately. While any Quattro3 can be daisy-chained 
(regardless of interface) the daisy chain power method requires all units in the chain to have 
some type of secondary interface card (Quattro3 301 will not work). The daisy chain power 
method will work with up to 8 consecutive units before requiring another power source.

Connector Panel

Satellite Unit 3

Satellite Unit 2

Master Unit (Unit 1)

Daisy Chain Cable

Connector Panel

Connect to next unit

Interface

Module

Interface

Module

Interface

Module

DOWN

DOWN

DOWN

UP

UP

UP

Summary of Contents for 301

Page 1: ...USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302 ...

Page 2: ...s guide will help you learn how to use your speakerphone and will reveal all the features that come with it The Quattro3 Q3 is a high quality conference speakerphone that will turn any room into a professionally sounding conference room It has an exceptionally large pickup and broadcasting range yet is small in size and discrete in design QUATTRO3 OVERVIEW L1 Function L2 Function Power Mute Volume...

Page 3: ...is either plugged into a power source or has a charged battery Your Quattro3 is ready to be used for an analog telephone call 1 2 3 1 2 CONNECT TO A COMPUTER This connection is for any session using your computer such as Voice Over IP applications Skype Vidyo etc Using the USB cable provided plug the mini USB side of the cable into the Q3 located on the connector panel below the unit Plug the USB ...

Page 4: ...in the Ring Level screen increase ring volume using and decrease using Once you are at your desired level use or to return back to the main screen OR OR dial new number then 1 2 Press to get a dial tone The screen will display the last dialed number Either select to redial by pressing 1 2 3 1 1 1 2 3 4 5 1 2 3 OR To view the last 10 dialed numbers click from the main screen then scroll up using an...

Page 5: ...ATIONS Turn unit ON push the Power Mute button The light will turn on Turn unit OFF push the Power Mute button and hold for 3 seconds The unit will beep 4 times and turn off The light will turn off Mute microphones push the Power Mute button once for less than three seconds The light will start blinking Unmute microphones push the Power Mute button once for less than three seconds The light will s...

Page 6: ...ll units in the chain must be Quattro3s POWERING THE DAISY CHAIN Every unit in the chain must be powered In order to do this there are two available options Power each unit separately using its own provided USB cable DC power supply or internal battery if applicable Power only the master unit using the Daisy Chain Power Kit This setup will require you to connect only the first unit to a power sour...

Page 7: ...ble unsnap the plastic cover and install the plastic arch that is included with the unit Make sure you slide the arch from below the hole and push its sides in until you feel a click EXTERNAL MIC SPEAKER MICROPHONE ONLY Connect the external microphone to the 3 5mm connector Select MIC ONLY in the Audio Setup Utility Microphone goes to tip SPEAKERS ONLY Connect the external speakers to the 3 5mm co...

Page 8: ... use the unit without plugging it into a wall socket or a computer The charge level of your battery is displayed on the bottom of the LCD screen When the unit is connected to a power source USB or power outlet the battery symbol will show that it is charging until the battery reaches full capacity When the Q3 is working off of the battery and is not connected to any other power source it will auto...

Page 9: ...ed direction Automatic voice level adjustment AGC Line echo canceler active when telephone interface is present Metal case and metal grill mesh for high RFI immunity and product durability Complies with FCC 47 CFR Part 68 and ACTA adopted technical criteria TIA 968 A Complies with FCC 47CFR part 15 ICES 003 2004 Issue 4 Class B AS NZS CISPR 22 2006 Class B EN 55022 1998 A1 00 A2 03 Class B EN61000...

Page 10: ...ase date for a warranty claim and display the RMA number on the outside of the shipping package THIS WARRANTY IS VOID IF The product has been damaged by negligence accident act of God or mishandling or has not been operated in ac cordance with the procedures described in the operating and technical instructions or The product has been altered or repaired by other than the Manufacturer or an author...

Reviews: