7. Life phases
7.6 Installation
Check for any damage or missing components after receipt of the electric cylinder. The electric
cylinder will be delivered read for operation without a controller.
The fixing of the electric cylinder is carried out using the fork heads on the push rod and the gear
housing. The assembly sequence described in these assembly instructions must be followed.
The transverse holes of the fork head have a diameter of 12 mm +0.1/0 mm. The
fastening bolts are not included in the scope of delivery.
The following instructions must be observed during installation:
The electric cylinder must not be operated electrically before being installed in its
final position.
This will otherwise adjust the set end positions of the electric cylinder.
•
The stroke end positions of the electric cylinder are set in the factory. The push rod is not
secured against twisting.
A rotation of the push rod or the joint head mounted on the thread of the push rod leads to an
adjustment of the end position.
In order to prevent the adjustment of the stroke and installation position, the red safety cord
must only be removed after installing the electric cylinder.
Forces and torque on the push rod acting laterally is not permitted.
Perform a test run.
•
•
•
•
•
Non observance of this procedure will lead to damage to the electric
cylinder! This nullifies the guarantee!
With regard to the installation position of the components, take care to
avoid crushing and shear points, especially when taking into consideration
any future applications.
•
50