![Phoenix Mecano DEWERT OKIN DUOMAT 7 HOME Installation Instructions Manual Download Page 22](http://html1.mh-extra.com/html/phoenix-mecano/dewert-okin-duomat-7-home/dewert-okin-duomat-7-home_installation-instructions-manual_1552024022.webp)
Installation
DUOMAT 7
22
43170 6.0
10
Close off the unused sockets using dummy plugs. The dummy plugs ensure that the sockets
are properly protected against any splashed water.
11
Attach the shield cover (as shown in Figure 13). More information is available in the "Connect-
ing a rechargeable battery" section of this document.
12
Connect the mains power plug.
6.2.2
Electrical connection
CAUTION
Work on electrical components should be conducted only when the mains power con-
nection is unplugged.
WARNING
Only personnel with the following training are qualified to work on the power cord or to
replace the power cord:
someone who has completed training in electronic motor assembly or,
someone with equivalent qualifications, or
someone who has successfully completed the appropriate DewertOkin training pro-
gram.
You should only work on the power cord when you are qualified to do so. Otherwise, a
properly qualified person should be found for this task.
Changing the primary fuses
Figure 11
Changing the primary fuses
A
Cover for mains junction compartment
B
Screws
C
Optional grounding bolt
D
Ground symbol
E
Primary fuse
E
E
B
D
A
C
B
B
B