RSd AMPLIFIERS 

2 CHANNEL OWNER’S MANUAL

Phoenix Gold International, Inc. • 9300 North Decatur St. Portland, OR 97203 • 503.286.9300 • www.phoenixgold.com

3. INPUT SENSITIVITY LEVEL CONTROL (SENS)

   The input sensitivity level can be varied from 200 mV to 8.0 volts depending 

on the output voltage of the source unit (refer to sub-section titled INPUT 
SENSITIVITY ADJUSTMENT).

4.  FILTER SELECT SWITCH 

  Set to:  HP - for mid and highs
   

BY (bypass) - for full range or when using external processing

   

LP - for subwoofer 

5.  FREQUENCY SELECTOR (FREQ)

  Allows variable adjustment from 40 to 400Hz when HP or LP are selected.

6.  VARIABLE BASS BOOST

 

  The bass boost will increase the output centered at 45Hz from 0 to 18dB

���

���

�����

����

�����

������

����

��������

�� ���

�� ���

�� �� ��

CONTROLS, INDICATORS, AND TERMINALS:

1. AUX OUTPUT (RCA)

   This output is full range and can be used to connect to another amplifier for 

system expansion.

2. LINE LEVEL INPUT (RCA)

   To be connected to RCA pre-amp outputs from a source unit (i.e., radio, 

tape deck or CD player).

SIGNAL INPUT

CONTROLS

Summary of Contents for RSD250.2

Page 1: ...e Please read your warranty and retain your receipt and original carton for possible future use Great product and competent installations are only one piece of the puzzle when it comes to your system...

Page 2: ...ty Any applicable implied warranties are limited in duration to the period of the express warranty as provided herein beginning with the date of the original purchase at retail and no warranties wheth...

Page 3: ...om as low as 200 mV to as high as 8 0 volts by adjusting the control on the Input Panel MULTI FUNCTION PROTECTION INDICATOR When the red protect indicator lights up it signi es a high operating temper...

Page 4: ...CH Set to HP for mid and highs BY bypass for full range or when using external processing LP for subwoofer 5 FREQUENCY SELECTOR FREQ Allows variable adjustment from 40 to 400Hz when HP or LP are selec...

Page 5: ...his connection allows for connection of our remote voltage display optional so that you can monitor the applied voltage at the ampli er in real time 13 LEFT RIGHT SPEAKER OUTPUT TERMINAL Used to conne...

Page 6: ...your installation purposes permanently mount the ampli er to selected location Figure 3 Typical System connection Note It is best to mount the ampli er to some form of insulating surface such as MDF s...

Page 7: ...rails steering column etc connecting one end to the ampli ers terminal and connecting the other end to a proper sized fuse link within 18 inches of the positive post on the battery If possible do not...

Page 8: ...source unit s fader control Check the ampli er s Input Sensitivity Level Frequent automatic ampli er shut down This indicates that the ampli er is operating at a continually undesirable high internal...