25 |
P a g e
Technical Data
Note: The voltage levels before/after the slash are valid for 12 V and 24 V systems respectively.
Technical Data
CIS-N-MPPT-LED 85/15
System voltage
12/24 V auto recognition
Max. charge current
15 A
Float charge
13.8/27.6 V (25 °C)
Main charge
14.4/28.8 V (25 °C), 0.5 h daily
Boost charge
14.4/28.8 V (25 °C), 2 h, activation: battery voltage < 12.3/24.6 V
Equalization charge
14.8/29.6 V (25 °C), 2 h, activation: battery voltage < 12.1/24.2 V (at least every 30 days)
Deep-discharge protection
11.0-12.0/22.0-24.0 V (by SOC)
11.0-11.9/22.0-23.8 V (by voltage)
Reconnect level
12.8/25.6 V
Overvoltage protection
15.5/31.0 V
Undervoltage protection
10.5/21.0 V
Max. PV panel voltage
50/85 V
Max. usable PV power
225 W @ 12 V, 450 W @ 24 V
Max. PV array power
250 Wp @ 12 V, 500 Wp@ 24 V
Temperature compensation (charge voltage)
-25 mV/K @ 12 V / -50 mV/K @ 24 V
Idle self-consumption
< 10 mA
Grounding
Common negative
Summary of Contents for CIS-N-MPPT-LED 85/15
Page 7: ...www phocos com 6 P a g e Erdungsbolze Eingang für PIR Bewegungsmelder Sicherung ...
Page 20: ...www phocos com 19 P a g e Fuse Grounding post Input for PIR motion sensor ...
Page 46: ...www phocos com 45 P a g e Entrée PIR pour détecteur de mouvement Fusible Mise à la terre ...
Page 71: ...www phocos com 70 P a g e 外壳接地端子 功率调节功能短时取消 信号输入 保险丝 ...