background image

 

21 

20  Control of lights for continuous and pulse mode   

Verification number lights flash in continuous or pulse mode can be selected by 

input control lights

. In this case the alarm 

is able to start, stop and monitor the correct lights flash number. In the case of setting a 

fixed period

, the correct number 

of flashes is only estimated - primary indication of alarm status. 

 

21 Confirm by lights 

Flashing by lights when alarm to lock or unlock doors is settable with this option (suitable for Peugeot cars).

 

 

22  Factory Reset  

All the optional features will be reset to the factory default value. 

 

SYSTEM INPUTS AND OUTPUTS 

3.1 

Shock Sensor Input 

Power supply for shock sensor is permanent. Negative triggering. 

3.2 

Additional Sensor Input 

Power  supply  for  additional  sensor  is  present  only  when  system  is  armed. 
Sensor  like  tilt,  ultrasonic  or  microwave  can  be  connected.  Negative 
triggering. 

 

3.3 

Door and Trunk Input  

System is triggered when Door+ input is connected to +12V or Door- input is 
connected to ground. Also, when trunk input is connected to ground system is triggered.  

 

3.4 

Ignition Input 

This input is connected to ignition wire. 

 

 

3.5 

Start-kill output 

Wire is grounded when system is armed or triggered. Max. current capacity -250 mA. 

 

3.6 

Output to the TRUNK 

When output is activated, +12V will appear on wire. Impulse length can be 0,5s, 4s, 40s or latch (option 12). 

 

3.7 

Output to the AUX1 

When output is activated, ground will appear on wire. Impulse length can be 0,5s, 4s, 40s or latch (option 13). Max. current 
capacity -250mA. 

3.8 

Output to the AUX2 

When  output  is  activated,  ground  will  appear  on  wire.  Impulse  length  can  be  0,5s,  4s,  40s  or  latch/60s.  (option  14).  Max. 
current capacity -250mA. 

 

3.9 

Output to the PAGER 

When alarm is triggered, PAGER output is switched to ground. Max. current capacity  -250mA. 

 

3.10 

Output to the SIREN 

Positive output (+12V) to the siren.  

 

3.11 

Security loop 

Alarm will be triggered when loop is cut. Suitable for caravan, car trailer, etc. 
  

3.12 

Output to Signal Lights 

This output is relay type (fig.5), so it can be used as negative as well as positive.   

 

3.13 

Input of lights control 

This input is connected to the wires hazard lights or direction indicators. Input response to a positive v12 V. Allows the 
actual illumination of lights in case the selected mode (continuous or pulse) and choice option 2 of feature 20.  

 

3.14 

Output PROG 

Connecting is used for setting programmable functions of alarm by software via USB adapter and PC. 

 

3.15 

Door LOCK, UNLOCK outputs 

Universal six relay output is possible to use for variable connection directly to actuators or to CDL’s control units. Length of 
lock / unlock impulses can be set (feature 1 and 2). 
Example of wiring diagram for door locking system:

 

input 

+12V 

GND 

Connection of sensor 

– front view. 

Summary of Contents for Mistral Max 2

Page 1: ...MODUL RNY AUTOALARM Mont ny manu l MODUL RN AUTOALARM Mont n manu l VEHICLE SECURITY SYSTEM Installer s manual SK CZ EN...

Page 2: ...o vek 1 potom 2 zapnutie alarmu s vypnut m senzorov alarm je vypnut s asn stla enie tla idiel postupn stla enie tla idiel Indik cia LED Ak je alarm zapnut LED blik v pomaly Pri poplachu LED blik r chl...

Page 3: ...nastav te nov k d Stla enie je indikovan bliknut m LED c Po uplynut 8 sek nd sir na p pne to kokr t ak je nov slo k du d Vypnite zapa ovanie 1 4 Servisn re im Pou itie servisn ho re imu je vhodn v pr...

Page 4: ...uzapnutie alarmu Zapnut Vypnut 18 Kontrola otvoren ch dver Vypnut Zapnut 19 Zamykanie od zapa ovania Vypnut Zapnut 20 Riadenie svetiel pre re im Plynul Pulzn Pevn doby Cez vstup KONTROLA SVETIEL 21 Po...

Page 5: ...kl panie sa impulz v dy ukon pri deaktiv cii alarmu Po as trvania impulzu je vypnut otrasov a pr davn senzor ako aj sn manie kufra maxim lne v ak 40 sek nd 12 D ka impulzu pre kufor Nastavenie doby tr...

Page 6: ...ukostrenie a 12V Vstup kufor reaguj ci na ukostrenie 3 4 Vstup od zapa ovania 15 Vstup sa prip ja na sp naciu skrinku a vodi 15 zapa ovanie 3 5 Blokovac v stup Pri aktivovanom alarme po as str enia p...

Page 7: ...Samotn doby sp nania rel je mo no nastavi v tabu ke riadky 1 a 2 Pr klady zapojen v stupov CZ Obr 1 Zapojenie pre centr lne zamykanie so sp na om v oboch dver ch Je potrebn motor na riadenie 12V Zamk...

Page 8: ...boch svetiel je nutn zapoji di dy K v stupu svetiel 23 12 V Obr 4 Pr klad zapojenia ovl dania svetiel pomocou sp na a v stra n ho svetla Sp na V stra n ho Svetla Ovl danie svetiel automobilu Kontakt r...

Page 9: ...1 19 oran ov v stup COM1 17 biely v stup NO1 18 lt v stup NC2 22 oran ierny v stup COM2 20 biely ierny v stup NO2 21 lt ierny odomykanie zamykanie poistka 15A poistka 5A poistka 15A poistka 15A Start...

Page 10: ...la tek Indikace LED Je li alarm zapnut LED blik v del ch intervalech P i poplachu LED blik rychle V servisn m re imu LED trvale sv t Byl li spu t n poplach pak LED po vypnut alarmu a p i otev en ch dv...

Page 11: ...d Stisknut je indikov no bliknut m LED c Po uplynut 8 sekund sir na p pne tolikr t kolik je nov slo k du d Vypn te zapalov n 1 4 Servisn re im Pou it servisn ho re imu je vhodn v p pad kdy bude autom...

Page 12: ...n n vypnuto upozor ov n zapnuto Vypnuto v dy 16 V stup na kufr S vypnut m alarmu Bez vypnut alarmu 17 Automatick znovuzapnut alarmu Zapnuto Vypnuto 18 Kontrola otev en ch dve Vypnuto Zapnuto 19 Zamyk...

Page 13: ...2 pro dotah oken v stup se aktivuje na dobu ur enou ve funkci 14 v dy p i aktivaci alarmu P i volb P ekl p n je impulz v dy ukon en p i deaktivaci alarmu B hem trv n impulzu je vypnut ot esov a p davn...

Page 14: ...t 250mA 3 6 V stup na kufr V stup se p i aktivaci p ipoj na 12V b hem doby uveden v tabulce dek 12 3 7 V stup pro AUX1 V stup se p i aktivaci p ipoj na kostru po dobu nastavenou v tabulce dek 13 Umo u...

Page 15: ...30 87 87a 87 85 86 Start Zap ACC Vyp Obr 3 Zapojen blokovac ho rel Rel je dod v no k alarmu K blokovac mu v stupu 9 K zapalov n 11 Obr 4 P klad zapojen ovl d n sv tel pomoc sp na e v stra n ho sv tla...

Page 16: ...stup NC1 19 oran ov v stup COM1 17 b l v stup NO1 18 lut v stup NC2 22 oran ern v stup COM2 20 b l ern v stup NO2 21 lut ern odemyk n zamyk n pojistka 15A pojistka 5A poistka 15A poistka 15A Start ON...

Page 17: ...LED is flashing slowly When the alarm is triggered LED is flashing quickly In valet mode LED is ON permanently Alarm memory with triggering sensor specification See description in point 1 8 1 SYSTEM I...

Page 18: ...s disarmed turn the ignition ON b Within 8 seconds press the valet switch 9 times c Siren will chirp 4 times d Press valet switch according to your new code 1 9 Each pressing the button is confirmed b...

Page 19: ...TH disarming WITHOUT disarming 17 Auto Rearming Enable Disable 18 Door Open Alert Disable Enable 19 Ignition Lock Disable Enable 20 Control of lights for modes continuous pulse Fixed periods by Input...

Page 20: ...e for trunk output When the option is set to latch the output connect to 12V when you press the button Disable the output is possible by repeated pressing button 13 AUX1 pulse duration Duration of neg...

Page 21: ...tivated 12V will appear on wire Impulse length can be 0 5s 4s 40s or latch option 12 3 7 Output to the AUX1 When output is activated ground will appear on wire Impulse length can be 0 5s 4s 40s or lat...

Page 22: ...were required To Start wire To ACC or ignition 87 30 87 87a 87 85 86 Start On ACC Off Figure 3 Wiring diagram for start kill relay Note Relay is delivered with alarm To output start kill 9 To ignitio...

Page 23: ...egative output NC1 19 orange output COM1 17 white output NO1 18 yellow output NC2 22 orange black output COM2 20 white black output NO2 21 yellow black UNLOCK LOCK fuse 15A fuse 5A fuse 15A fuse 15A S...

Page 24: ...24...

Reviews: