21
20 Control of lights for continuous and pulse mode
Verification number lights flash in continuous or pulse mode can be selected by
input control lights
. In this case the alarm
is able to start, stop and monitor the correct lights flash number. In the case of setting a
fixed period
, the correct number
of flashes is only estimated - primary indication of alarm status.
21 Confirm by lights
Flashing by lights when alarm to lock or unlock doors is settable with this option (suitable for Peugeot cars).
22 Factory Reset
All the optional features will be reset to the factory default value.
3
SYSTEM INPUTS AND OUTPUTS
3.1
Shock Sensor Input
Power supply for shock sensor is permanent. Negative triggering.
3.2
Additional Sensor Input
Power supply for additional sensor is present only when system is armed.
Sensor like tilt, ultrasonic or microwave can be connected. Negative
triggering.
3.3
Door and Trunk Input
System is triggered when Door+ input is connected to +12V or Door- input is
connected to ground. Also, when trunk input is connected to ground system is triggered.
3.4
Ignition Input
This input is connected to ignition wire.
3.5
Start-kill output
Wire is grounded when system is armed or triggered. Max. current capacity -250 mA.
3.6
Output to the TRUNK
When output is activated, +12V will appear on wire. Impulse length can be 0,5s, 4s, 40s or latch (option 12).
3.7
Output to the AUX1
When output is activated, ground will appear on wire. Impulse length can be 0,5s, 4s, 40s or latch (option 13). Max. current
capacity -250mA.
3.8
Output to the AUX2
When output is activated, ground will appear on wire. Impulse length can be 0,5s, 4s, 40s or latch/60s. (option 14). Max.
current capacity -250mA.
3.9
Output to the PAGER
When alarm is triggered, PAGER output is switched to ground. Max. current capacity -250mA.
3.10
Output to the SIREN
Positive output (+12V) to the siren.
3.11
Security loop
Alarm will be triggered when loop is cut. Suitable for caravan, car trailer, etc.
3.12
Output to Signal Lights
This output is relay type (fig.5), so it can be used as negative as well as positive.
3.13
Input of lights control
This input is connected to the wires hazard lights or direction indicators. Input response to a positive v12 V. Allows the
actual illumination of lights in case the selected mode (continuous or pulse) and choice option 2 of feature 20.
3.14
Output PROG
Connecting is used for setting programmable functions of alarm by software via USB adapter and PC.
3.15
Door LOCK, UNLOCK outputs
Universal six relay output is possible to use for variable connection directly to actuators or to CDL’s control units. Length of
lock / unlock impulses can be set (feature 1 and 2).
Example of wiring diagram for door locking system:
input
+12V
GND
Connection of sensor
– front view.
Summary of Contents for Mistral Max 2
Page 24: ...24...