DMX Operation
This section is contains individual DMX channel maps for each luminaire covered in this manual -
VL440 Spot, VL770 Spot, and VL880 Spot. Refer to the corresponding DMX channel map for your
fixture.
•
VL440 Spot Channel Mapping
•
VL770 Spot Channel Mapping
•
VL880 Spot Channel Mapping
Iris Operation
Important Notes and Warnings
•
Operating fixtures with either Iris 1 or Iris 2 using a software prior to
08/08/12
will cause the iris
to close too far, which will result in damage to the iris and this damage will not be covered under
the warranty.
•
If iris closes very small, you have an older version of software and MUST update to the software
released 08/08/12 or later.
•
If iris is not set to the correct iris setting, you will experience the following symptoms:
Iris Selection / Configuration Operation
•
This option has been added as described in software technical bulletin LSW-069. LSW-069 Stated
-
Installation of this software to all VL440 spot, VL770 spot, and VL880 spot luminaires
manufactured prior to 7/20/12 will be effected that their iris will not close as much as previous
software versions. VL770 spot and VL880 spot luminaires manufactured after 7/20/12 will close
further, but not as far. A long term solution to close the original irises is forthcoming.
•
All VL440/VL770/VL880 spot luminaires manufactured prior to 07/20/12 and all VL440 spot
luminaires (manufactured prior to and after 07/20/12) are built using iris assembly 22.9687.0230.
These iris assemblies are described in the menu selection as "IRIS 1".
•
All VL770/VL880 spot luminaires manufactured after 07/20/12 are built using iris assembly
22.9687.0235. These iris assemblies are described in the menu selection as "IRIS 2".
•
Users now have, in this software release, a menu option to set their fixture to the appropriate iris
setting so all VL440/VL770/VL880 fixtures operate in the same manner during iris opening/
closing operation.
Iris Installed
Iris Setting
Symptom
Iris 1
Iris 2
There will be a delay before the iris will begin to close and
the iris will not close as far.
Iris 2
Iris 1
The iris will not go completely out of the gate.
Summary of Contents for Variolite VL440
Page 1: ......
Page 13: ...FOREWORD 02 9687 0001 C 31 October 2013 xi ...
Page 14: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL xii 31 October 2013 02 9687 0001 C ...
Page 18: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 4 31 October 2013 02 9687 0001 C ...
Page 22: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 4 31 October 2013 02 9687 0001 C Notes ...
Page 94: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 76 31 October 2013 02 9687 0001 C Notes ...
Page 115: ......