Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. 10 amps is
required.
Depending on the application, the luminaire’s AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code:
* International (Harmonized) Standard
WARNING:
DO NOT connect to three-phase Delta service in countries with 240 volt power.
Note:
The lamp will not strike below 180 volts RMS. The following socket configurations are typical;
other countries can use different socket configurations.
For single-phase power at 200-240 volts RMS:
For three-phase power at 208 volts RMS:
Wire *
Connection
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
Connection
Pin
AC Neutral
X
AC Line
Y
Ground (Earth)
G
Connection
Pin
Phase 1
X
Phase 2
Y
Ground (Earth)
G
X
Y
G
X
Y
G
Summary of Contents for Vari-lite VL3500 Wash FX Luminaries
Page 1: ......
Page 13: ...FOREWORD 02 9686 0001 B 01 June 2009 xi ...
Page 14: ...VARI LITE VL3500 WASH VL3500 WASH FX LUMINAIRES USER S MANUAL xii 01 June 2009 02 9686 0001 B ...
Page 18: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL xvi 01 June 2009 02 9686 0001 B Notes ...
Page 42: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 24 01 June 2009 02 9686 0001 B Notes ...
Page 66: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 48 01 June 2009 02 9686 0001 B Notes ...
Page 98: ...VARI LITE VL3500 WASH LUMINAIRE USER S MANUAL 80 01 June 2009 02 9686 0001 B Notes ...
Page 99: ......