Philips TuffGuard

High Intensity Discharge

Coated Lamps—HPS Lamps

Ordering, Electrical and Technical Data

Max.

Rated

Approx.

Product

Nom.

Pkg.

Avg. Life

Initial

Number

Description

Watts

Volts

Qty.

Bulb

Base

(Hrs)

1

Lumens

2

Availability

20218-4

C70S62 12PK TG

70

52

12

ED-23

1

2

Mogul

24,000

6500

Made to Order

20219-2

C100S54 12PK TG

100

55

12

ED-23

1

2

Mogul

24,000

9400

Made to Order

20220-0

C150S55 12PK TG

150

55

12

ED-23

1

2

Mogul

24,000

15,800

Made to Order

20222-6

C250S50 12PK TG

250

100

12

ED-18

Mogul

24,000

27,000

Stocked

20458-6

C50S68/M 12PK TG

50

52

12

BF-55

Medium

24,000

4000

Made to Order

20460-2

C100S54/M 12PK TG

100

55

12

BF-55

Medium

24,000

9500

Made to Order

1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Protective coating may reduce actual lumens by up to 5%.

Above specifications are subject to change without notice.

WARNINGS:

• Coating can withstand bulb wall temperatures up to 500°F, subject to the following conditions:

1) Lamp must be installed and operated in ambient temperature below 150°F.
2) Lamp is not used in fixture that does not allow heat dissipation.

RECOMMENDED WARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS
For High Pressure Sodium Lamps

R

“WARNING:

These lamps must be operated in fixtures designed for use with High Pressure Sodium

lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch

the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum
in the outer bulb may cause glass to fly if the glass is struck.Operating the lamp improperly may result in

PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.

1. If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.

2. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended
by ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B. For total supply load refer to ballast manufacturers electrical data.

3. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

4. Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.

5. If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition

of the bulb glass.

6. Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and

its immediate vicinity, as this may lead to very early lamp failure.

7. Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the contents

or fragments.

8. The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state and local

requirements.

Made to order requires 3 week lead time
(No product returns on made to order lamps)

Summary of Contents for TUFFGUARD Series

Page 1: ...switch start and high pressure sodium lamps that provide long life high efficiency and high lumen output PhilipsTuffGuard coated lamps Contains glass fragments in the event the lamp is accidentally dropped or broken Easy to clean non stick coating Coating is not designed to contain an arc tube rupture Ideal for manufacturing and warehouse applications TUFFGUARD SERIES ...

Page 2: ...ding environment If such a rupture were to happen THERE IS A RISK OF PERSONAL INJURY PROPERTY DAMAGE BURNS AND FIRE Certain lamps that will retain all the glass particles should inner arc tube rupture occur are commercially available from Philips Lighting Company RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE Allowing lamps to operate until they fail is not advised and may increase the possibil...

Page 3: ... or misapplication If the arc tube ruptures for any reason the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment If such a rupture were to happen THERE ISA RISK OF PERSONAL INJURY PROPERTY DAMAGE BURNS AND FIRE These lamps are designed to retain all the glass particles should an arc tube rupture occur The following operating instructions ar...

Page 4: ...ambient temperature below 150 F 2 Lamp is not used in fixture that does not allow heat dissipation RECOMMENDED WARNINGS CAUTIONS AND OPERATING INSTRUCTIONS For High Pressure Sodium Lamps R WARNING These lamps must be operated in fixtures designed for use with High Pressure Sodium lamps The fixture wattage rating must match the wattage indicated on the outer glass bulb Do not scratch the outer bulb...