LEAKAGE CURRENT COLD CHECK
1. Unplug the ac line cord and connect a jumper between the two prongs of the plug.
2. Turn on the power switch.
3. Measure the resistance value between the jumpered ac plug and all exposed cabinet parts of the receiver,
such as screw heads, antennas, and control shafts. When the exposed metallic part has a return path to the
chassis, the reading should be between 1 megohm and 5.2 megohms. When the exposed metal does not
have a return path to the chassis, the reading must be infinity. Remove the jumper from the ac line cord.
LEAKAGE CURRENT HOT CHECK
1. Do not use an isolation transformer for this test. Plug the completely reassembled receiver directly into
the ac outlet.
2. Connect a 1.5k, 10W resistor paralleled by a 0.15uF. capacitor between each exposed metallic cabinet
part and a good earth ground such as a water pipe, as shown below.
3. Use an ac voltmeter with at least 5000 ohms/volt sensitivity to measure the potential across the resistor.
4. The potential at any point should not exceed 0.75 volts. A leakage current tester may be used to make
this test; leakage current must not exceed 0.5mA. If a measurement is outside of the specified limits,
there is a possibility of shock hazard. The receiver should be repaired and rechecked before returning it
to the customer.
5. Repeat the above procedure with the ac plug reversed. (Note: An ac adapter is necessary when a
polarized plug is used. Do not defeat the polarizing feature of the plug.)
OR
With the instrument completely reassembled, plug the ac line cord directly into a 120Vac outlet. (Do not
use an isolation transformer during this test.) Use a leakage current tester or a metering system that
complies with American National Standards Institute (ANSI) C101.1 Leakage Current for Appliances and
Underwriters Laboratories (UL) 1410, (50.7). With the instrument ac switch first in the on position and
then in the off position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed
metal parts of the instrument (antennas, handle brackets, metal cabinet, screw heads, metallic overlays,
control shafts, etc.), especially any exposed metal parts that offer an electrical return path to the chassis.
Any current measured must not exceed 0.5mA. Reverse the instrument power cord plug in the outlet and
repeat the test. See the graphic below.
Summary of Contents for TP2784C101
Page 1: ......
Page 5: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ...27G7 7585 ...
Page 71: ...27G7 7585 ...
Page 72: ...27G7 7585 ...
Page 73: ...27G7 7585 ...
Page 75: ...All Models 7585 WIRING DIAGRAM ...
Page 76: ...All Models 7585 POWER SUPPLY SCHEMATIC A1 ...
Page 77: ...All Models 7585 HORIZONTAL DEFLECTION SCHEMATIC A2 ...
Page 78: ...All Models 7585 VERTICAL DEFLECTION SCHEMATIC A3 ...
Page 79: ...All Models 7585 TUNER SCHEMATIC A4 ...
Page 80: ...All Models 7585 VIDEO PROCESSOR SCHEMATIC A5 ...
Page 81: ...All Models 7585 SYNC SCHEMATIC A6 ...
Page 82: ...All Models 7585 RGB PROCESSOR SCHEMATIC A7 ...
Page 83: ...All Models 7585 MICROPROCESSOR SCHEMATIC A8 ...
Page 84: ...All Models 7585 AUDIO PROCESSOR SCHEMATIC A10 A11 ...
Page 85: ...All Models 7585 AUDIO OUTPUT SCHEMATIC A12 ...
Page 86: ...All Models 7585 IO SWITCHING SCHEMATIC A13 ...
Page 87: ...All Models 7585 FRONT AV SCHEMATIC A14 ...
Page 88: ...All Models 7585 FRONT CONTROL SCHEMATIC A15 ...
Page 89: ...All Models 7585 CRT PANEL SCHEMATIC B ...
Page 92: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 GUIDE PLUS SCHEMATIC K1 ...
Page 93: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 GUIDE PLUS SCHEMATIC K2 ...
Page 94: ...All Models 7585 JACK PANEL SCHEMATIC L1 ...
Page 95: ...All Models 7585 JACK PANEL SCHEMATIC L2 ...
Page 96: ...USED ONLY IN MODELS 32PT70B101 7585 SIDE AV PANEL SCHEMATIC ...
Page 100: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 VIRTUAL DOLBY PANEL SCHEMATIC V ...
Page 101: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE WINDOW PIP W1 ...
Page 102: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE WINDOW PIP W2 ...
Page 103: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE WINDOW PIP W3 ...
Page 104: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE WINDOW PIP W4 ...
Page 105: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE WINDOW PIP W5 ...
Page 106: ...All Models 7585 MAIN CHASSIS CBA TOP ...
Page 107: ...All Models 7585 MAIN CHASSIS CBA BOTTOM ...
Page 112: ...All Models 7585 GUIDE PLUS CBA TOP ...
Page 113: ...All Models 7585 GUIDE PLUS CBA BOTTOM ...
Page 114: ...All Models 7585 JACK PANEL CBA TOP ...
Page 115: ...All Models 7585 JACK PANEL CBA BOTTOM ...
Page 116: ...USED ONLY IN MODELS 32PT70B101 7585 SIDE A V PANEL CBA TOP ...
Page 117: ...USED ONLY IN MODELS 32PT70B101 7585 SIDE A V PANEL CBA BOTTOM ...
Page 122: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 VIRTUAL DOLBY CBA TOP ...
Page 123: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 VIRTUAL DOLBY CBA BOTTOM ...
Page 124: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE PIP CBA TOP ...
Page 125: ...USED ONLY IN MODELS 27PT40B101 32PT70B101 7585 DOUBLE PIP CBA BOTTOM ...
Page 126: ...TYPICAL TABLE MODEL EXPLODED VIEW ...