2. Connect the power adapter

 

3. Adjust the input volume

For correct operation, make sure you adjust the 

stethoscope and your  TV (with 3.5mm audio 

output) to an optimal sound volume level. 

On the stethoscope, make sure the 

volume is set to medium to low level.

On the TV, make sure the volume is set to 

medium to high level.

 

»

The docking station now switches on 

automatically.

When the volume level is good enough, 

stop re-adjusting the volume level on the 

TV.  Use the stethoscope to re-adjust the 

volume level instead.

Note

 

If the volume level at TV is too low, the docking station 

will not switch on.

 

If the volume level at TV is set to relatively low, the 

docking station will intermittently switch off.

 

If you hear background noise in the stethoscope, turn 

up the volume of your TV. 

Install the supplied batteries

The first battery

Your stethoscope comes with a high quality 

rechargeable lithium-polymer battery to 

maximize battery lifetime. Insert/remove the 

first battery as follows:

  

 

Note

 

Over time the capacity of the battery will decrease. You 

can order replacement batteries through the Philips 

service centers or online stores at 

www.shop.philips.

com

The spare battery

The spare battery extends the operating time 

when the first battery needs re-charging. Insert 

the spare battery as follows:

 

Summary of Contents for SSC5001

Page 1: ...www philips com support User manual Always there to help you Register your product and get support at SSC5001 SSC5002 SSC5011 SSC5012 Question Contact Philips ...

Page 2: ......

Page 3: ...e 8 Auto switch on off 8 Adjust the listening volume 8 Adjust the left right balance 8 Amplify the environmental sound 8 Equalizer EQ 8 Store and charge the stethoscope 8 5 LED and sound indication 9 LED indication 9 Sound indication 9 6 Care and maintainence 10 Clean the stethoscope and docking station 10 Clean the ear caps 10 7 Accessories 11 8 Technical data 12 9 Notice 13 Declaration of confor...

Page 4: ...information Caution To prevent fire or shock hazard Always keep this product dry Do not expose it to excessive heat by heating equipment or direct sunlight No naked flame sources such as lighted candles should be placed on the apparatus Do not allow your product to be submerged in water To clean the product Use a slightly dampened chamois cloth Do not use cleansing agents containing alcohol spirit...

Page 5: ...thoscope Docking station Power adapter 3 5mm audio cable Optical cable RCA adapter Rechargeable lithium polymer battery Spare ear caps x 2 pairs User manual Quick start guide Note In packs with two stethoscopes there are additional stethoscope and battery 4XLFN VWDUW JXLGH ...

Page 6: ... AUDIO IN Audio input b AUDIO IN OPTICAL IN switch c Optical input d ATT Attenuation of audio input signal switch e POWER Power the docking station on or off f Power adapter jack g Battery charging slot h Battery charging indicator i Stethoscope charging indicator j Stethoscope charging slot k Equalizer EQ button l Equalizer EQ indicators EQ 1 voice emphasis EQ 2 treble boost EQ 3 bass boost c d b...

Page 7: ...ation and another side to the 3 5mm audio output switch to AUDIO IN switch ATT to 0dB switch to 8dB if the sound volume is too high ForTV or other devices with RCA output connect one side of the supplied RCA adapter to RCA output of the audio device and another side to the supplied 3 5mm audio cable Connect the remaining side of the 3 5mm audio cable to the 3 5mm audio input of the docking station...

Page 8: ...tTV is too low the docking station will not switch on If the volume level atTV is set to relatively low the docking station will intermittently switch off If you hear background noise in the stethoscope turn up the volume of yourTV Install the supplied batteries The first battery Your stethoscope comes with a high quality rechargeable lithium polymer battery to maximize battery lifetime Insert rem...

Page 9: ... battery capacity and lifetime You can charge one stethoscope per each time Normally a full charge takes 2 5 hours 1 Power on the docking station 2 Place the stethoscope on the docking station The orange charging LED flashes If the spare battery is inside the charging slot the orange charging LED of the spare battery will flash too ...

Page 10: ...he left right balance to make your both ears hear well see Overview of the stethoscope on page 4 ON OFF Amplify the environmental sound You can press the microphone button to turn off the sound of theTV and amplify the environmental sound and conversations see Overview of the stethoscope on page 4 Press the microphone button again to return to the audio device Equalizer EQ You can press the EQ but...

Page 11: ...hite Connected to the stethoscope White Searching White LED flashes Equalizer EQ On White Off Off Stethoscope Off Off Wireless mode White Ambient mode Orange Connection lost White LED flashes Low battery level Orange LED flashes Sound indication Status Sound signal The stethoscope is on 1 short beep Low battery level 1 beep per minute for 4 minutes Battery goes out soon 2 beeps Reach max min volum...

Page 12: ...ly wet cloth to clean the product gently Clean the ear caps 1 Remove the ear caps carefully from the stethoscope 2 Clean the ear caps with warm soap water 3 Dry the ear caps thoroughly Note The ear caps need to be replaced for a regular period of time You can order replacement ear caps through the Philips service centers or online stores at www shop philips com ...

Page 13: ...nal accessories You can order extra accessories through the Philips service centers or online stores at www shop philips com for replacement Extra charger SSA5CS Stethoscope SSA5HS Rechargeable lithium polymer battery SSA5BA Ear caps SSA5ET ...

Page 14: ... RF solution Auto power on off Attenuator on off Extra slot for second battery charging Equalizer EQ x 3 Battery Rechargeable lithium polymer battery 3 7V 350 mAh Adapter Philips SVV 005 050 055 A2 input 100 240V 50 60 Hz output 5Vdc 550 mA Weight and dimensions Stethoscope 65 grams 216 1 x 158 9 x 21 5 mm H x W x D Docking station 120 grams 41 2 x 123 0 x 100 2 mm H x W x D Note Specifications ar...

Page 15: ...ich cannot be disposed of with normal household waste Inform yourself about the local separate collection system for electrical and electronic products and batteries Follow local rules and never dispose of the product and batteries with normal household waste Correct disposal of old products and batteries helps prevent negative consequences for the environment and human health Removing the disposa...

Page 16: ... station away from them The stethoscope is at a location with thick walls Move the docking station away from them Adjust the ATTsetting see Overview of the docking station on page 4 Adjust the volume of the audio device When I move my head I hear interfering noise The interference can be caused by another wireless device like Bluetooth WiFi router or 2 4 GHz devices Move the wireless device away T...

Page 17: ...15 EN ...

Page 18: ...der the responsibility of Gibson Innovations Ltd and Gibson Innovations Ltd is the warrantor in relation to this product Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N V and are used under license from Koninklijke Philips N V UM_SSC500x_501x_10_EN_V3 0 wk1550 0168 ...

Reviews: